Laserfiche WebLink
'L' � <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2575B1 sf ADS 2017 Builder Name: Lennar Homes 0103 <br /> street: 3210 Moulden Hollow Drive Permit Office: C� �Ze hyrhills <br /> City,State,Zip: ,FL, Permit Number• �� �� <br /> Owner. Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:. Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ftz <br /> b.Concrete Block-Int Insul,E�erior R=4.1 996.67 ftZ <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 <br /> 4. Number of Bedroams 4 d.N/A R= ftz <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1489.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 2582 b.N/A R= ft2 <br /> c.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 11.Ducts R ftz <br /> 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 <br /> a. U-Factor� Dbl,U=0.54 71.25 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 297.8 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor� Dbl,U=0.56 71.00 ftZ 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor: Dbl,U=0.56 33.33 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ft2 a.Electric Heat Pump 17.5 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 1.190 ft. <br /> Area Weighted Average SHGC: 0.300 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. FloorTypes (2582.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftZ b. Conservation features <br /> b.Floor Over Other Space R=0.0 1049.00 ft2 None <br /> c.other(see details) R= 440.00 ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.47 pASS <br /> Total Baseline Loads: 74.41 <br /> I hereby certify that the plans and specifications covered by Review of the plans and :a�'T�iS�'��.�_ •. <br /> this calculation are in compliance with the Florida Energy specifications covered by this "_:�- ' p- <br /> q�i �=?;?- "�{c <br /> Code. ' , calculation indicates compliance , ,�, r,;; ' a,.�,,.�� -.rs+ <br /> '�r, c:�::�a��. .�`_ : <br /> 4 'w�.'�1:-� ' - <br /> �ave ���C� w i t h t h e F l o r i d a E n e r g y C o d e. � t+' r�t,+-;.,�;,.,,::;,,.,.,,� ti,� <br /> h� . <br /> PREPARED BY: Before construction is completed � _ �� '` _ ; � <br /> DATE. this building will be inspected for � ` `f`F � . �, <br /> compliancewith Section 553.908 ' *, --�.��-' ;" -� <br /> I hereb certi that this buildin as desi ned,is in com liance Florida Statutes. .�,- <br /> Y fY 9, 9 P . '� . - _., .�a. < <br /> with the Florida Energy Code. `CaL?`y{�,'�' ,: <br /> OWNER/AGENT: BUILDING OFFICIAL: / <br /> DATE: �� � � DATE: 7 ' ' � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory�ealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> � - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.070 Qn for whole house. <br /> 8/14/2017 11.35 AM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 <br />