18-19309
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19309
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2018 7:44:17 AM
Creation date
9/24/2018 7:44:15 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19309
Building Department - Name
LENNAR HOMES LLC
Address
3210 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 T <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> � Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2575B1 sf ADS 2017 Builder Name: Lennar Homes 0103 <br /> street: 3210 Moulden Hollow Drive Permit ottice: City of Zephyrhills <br /> City,State,Zip: ,FL, " Permit Number <br /> Owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2613:1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ftz � <br /> b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftZ <br /> 4. Number of Bedrooms 4 d.N!A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1489.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 2582 b.N/A R= ftZ <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11.Ducts R ft2 <br /> 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 <br /> a. U-Factor: Dbl,U=0.54 71.25 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 297.8 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 71.00 ft2 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor• Dbl,U=0.56 33.33 ftz <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 17.5 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 1 190 ft. <br /> Area Weighted Average SHGC: 0.300 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. FloorTypes (2582.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftZ b. Conservation features <br /> b.Floor Over Other Space R=0.0 1049.00 ftZ None <br /> c.other(see details) R= 440.00 ft2 15.Credits Pstat <br /> Total Proposed Modified Loads: 74.47 pASS� <br /> Glass/Floor Area: 0.068 <br /> Total Baseline Loads: 74.41 <br /> I hereby certify that the plans and specifications covered by Review of the plans and r�='T�:��`,�j�,. -._ <br /> this calculation,are in compliance with the Florida Energy , specifications covered by this .�'4� '��_,�,-��0� -. <br /> Code. � calculation indicates compliance - ,c,��l;�; '' __�a;��ti�.K+ <br /> with the Florida Energy Code. h' jir,+�"%�;:;::�.�';;:���,t3 <br /> ,�av2 �GaI�iGGt ' -�... � � <br /> PREPARED BY: Before construction is completed cr� � � �- <br /> DATE. this building will be inspected for �' "���4_ ° � <br /> compliance with Section 553.908 ,.. •��• - , �,�. <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. :� <br /> Y fY 9� 9 P �".'`-.-.. <br /> with the Florida Energy Code. CO.�j yyr;'�� <br /> OWNER/AGENT' BUILDING OFFICIAL: <br /> DATE: DATE: - - <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.070 Qn for whole house. <br /> 8/14/2017 11:35 AM EnergyGaugeOO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br /> J <br />
The URL can be used to link to this page
Your browser does not support the video tag.