Laserfiche WebLink
Single Family'�Dwelling <br /> Plan Review Comments <br /> l. F.F.E. shall be a minimuan of 8" above the road elevation and an engineered site plan, <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Gompaction test required if 24" or more of f 11 dirt is brought in at any one place. <br /> 4. Tie in survey required before pouz-�ng concrete. <br /> 5. Driveways require a R.O.W. use permit. A114 sides of drzveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. A11 praperty markers shall be uncavered and rnarked at tirne of first inspection. <br /> 8. All A.D.A. requirements shall be met, <br /> 9. No electric,plumbing,mechanical, or framing shall be covered withaut an inspection and <br /> appraval first. <br /> 10. AII Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall nat be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P6Q7.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" abave finished grade. M1308.1 <br /> 14. Return air in all bedrooms. F.B.C. M162Q4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 af the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R3Q8.4 of the F.B.C. <br /> 17. All rn.eans of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R'702.4.2 F.B.C. <br /> 19. Combinatian-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 2Q. Carbon monoxide alarms will be required in new cansn-uction that uses fassil-burning heating <br /> ar appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. A11 plumbing,mechanical, and electrical shall be separate fram unit to unit. This includes a11 <br /> underground plumbing and electric. <br /> 22. Ali 2Q08 N.E.C. Codes will be enforced. <br /> 23. Tamper-Resistant Receptacles in accordance with 406.11 of the 200$ N.E.0 <br /> 24. In accordance with the Land Develapment Cade, lats shall be sodded befare finai at least 10 <br /> feet around the structure. <br /> Z5.A capy of the ener�v cacls shall be with pet mit ut all titnes <br /> 26. COpy of final insulatian renort shall be provided with permit before finax <br /> F.F.E.-Finished F2oor Elevatipn <br /> F.B.C- Florida Building Code 5�'Edition <br /> R.O.W.-Right af Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2008) <br />