My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19366
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19366
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2018 9:43:49 AM
Creation date
9/24/2018 9:43:47 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19366
Building Department - Name
LENNAR HOMES LLC
Address
6659 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• � � ' , w <br /> Manual S Compliance Report Job: 2421B sf ADS <br /> Date: 9/27/2017 <br /> Entire House By: DaveAldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York Ave,Hudson <br /> � � ' • � <br /> For� Lennar Homes <br /> • • • • • <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 27957 Btuh Entering coil DB: 75.7°F <br /> Outdoor design WB. 77.3°F Latent gain: 3433 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75:0°F Total gain: 31390 Btuh <br /> Indoor RH: 50% Estimated airflow: 1200 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230"++TDR <br /> Actual airflow: 1200 cfm ' <br /> Sensible capacity: 29070 Btuh 104% of load <br /> Latent capacity: 5130 Btuh 149% of load <br /> Total capacity' 34200 Btuh 109% of load SHR. 85% <br /> . • � <br />' Design Conditions <br /> Outdoor design DB ` 30.8°F � Heat loss. 34613 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230"++TDR <br /> Actual airflow: 1200 cfm <br /> Output capacity: 32800 Btuh 95% of load Capacity balance: 33 °F <br /> Supplemental heat required: 1813 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow� 1200 cfm <br /> Output capacity� 0 kW 0% of load Temp. rise: 0 °F <br /> Meets are all requirements of ACCA Manual S. <br /> ,� wri htsoft� 2017Sep-27 06.46:54 <br /> 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 <br /> � ...th CBA27UHE AH's12421 sf ADS template 3 ton.rup Calc=MJ8 Front Door faces:SW <br />� <br />
The URL can be used to link to this page
Your browser does not support the video tag.