Laserfiche WebLink
: , , � <br /> • Manual S Compliance Report Job: 2600B sf ADS <br /> Date: 9/2512017 <br /> Entire House By: Dave <br /> Bayonet Plumbing Heating and Air ' <br /> ' • - • � <br /> For: Lennar Homes <br /> • . • • • <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 33284 Btuh Entering coil DB: 75.6°F <br /> Outdoor design WB: 77.3°F Latent gain: 3401 Btuh Entering coil WB. 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 36685 Btuh <br /> Indoor RH: 50% Estimated airflow� 1400 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-042-230-21+CBA27UHE-042-230*++TDR <br /> Actual airflow: 1400 cfm <br /> Sensible capacity: 35700 Btuh 107% of load <br /> Latent capacity� 6300 Btuh 185% of load <br /> Total capacity: 42000 Btuh 114% of load SHR: 85% <br /> • � • <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss• 39282 Btuh Entering coil DB: 69.7°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-042-230-21+CBA27UHE-042-230*++TDR <br /> Actual airflow: 1400 cfm <br /> Output capacity: 42000 Btuh 107% of load Capacity balance: 29 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+Na <br /> Actual airtlow: 1400 cfm <br /> Output capacity� 0 kW 0% of load Temp. rise: 0 °F <br /> Meets are all requirements of ACCA Manual S. <br /> .c. wri htsoft� 2017-Sep-251148:10 <br /> �, 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 <br /> �� .ith CBA27UHE AH's\2600 sf ADS drawn 3.5 ton.rup Calc=MJS Front Door faces:SE <br />