My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19369
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19369
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2018 10:29:26 AM
Creation date
9/24/2018 10:29:22 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19369
Building Department - Name
DR HORTON INC
Address
6904 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, h <br /> , Manual S Compliance Report Job: - <br /> -�- wrightsoft� Date: Oct 10,2014 <br /> Entire House By: <br /> Progressive Air Systems, Inc - <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> � • ' � • <br /> For: DR Horton/Express <br /> Lot 3 Blk 7 Silverado Ranch, Zephyrhills, FL� <br /> • . • • • <br /> Design Conditions " <br /> Outdoor design DB: 91.2°F Sensible gain: 20893 Btuh Entering coil DB: 75.4°F <br /> Outdoor design WB: 77.1°F Latent gain: 2966 Btuh Entering coil WB: 62.7°F <br /> Indoor design DB: 75.0°F Total gain: 23859 Btuh <br /> Indoor RH: 50% Estimated airflow: 1000, cfm <br /> Manufacture'r's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Sensible capacity: 23270 Btuh 111%of load <br /> Latent capacity: 3914 Btuh 132%of load <br /> Total capacity: 27184 Btuh 114%of load SHR: 86% <br /> • • • <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 21100 Btuh Entering coil DB: 69.8°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14N6030'**"A+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Output capacity: 25604 - Btuh 121%of load Capacity balance: 32 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F , <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: - . <br /> Actual airflow: 1000 cfm <br /> Output capacity: 6.6 kW 107%of load Temp. rise: 20 °F <br /> Meets are all r uirements of ACCA Manual S. - <br /> eG <br /> ... wri htsofts 2017-Oct-3012:01•18 <br /> � 9 Right-Sulte�Universal 20i7 17.0.21 RSU25554 Page 1 <br /> ...on\Wrightsoft Files\E�ress homes\Cali 4EBB.rup Calc=MJ8 House faces: W <br />
The URL can be used to link to this page
Your browser does not support the video tag.