My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19372
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19372
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2018 10:32:06 AM
Creation date
9/24/2018 10:32:03 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19372
Building Department - Name
DR HORTON INC
Address
6912 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, � <br /> FORM R405-20:14 <br /> FLORIDA ENERGY EFFICIENlCY CODE FOR BUILDING CONSTRUCTION ' <br /> - - Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Hayden 4EHB Elev D . Builder Name: DRH 6cpress Homes / <br /> St�et: P �Lj�P/y��' l n��l J +l'�:I.`��r� � PerrriitOffice: �''�`�..e/ � ��.r�l-+u�� <br /> Cit ,State,Zi Ze fi rhi Is,`FLL� �� Permit Number: � �37 Z <br /> Owner: 4I X Jurisdiction: (o[C60b <br /> Design Location: FL,Tampa �'1 � County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2614.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=11.0 1285.30 ftz <br /> b.Concrete Block-Int Insul,Exterior R=4 1 996.67 ftz <br /> 3. Number of units,if multipie family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ft2 <br /> 4. Number of Bedrooms 5 d.N/A R= ftz , <br /> 10.Ceiling Types (1541.0 sqft.) insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 2605 b.N/A R= ftz <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftz <br /> ' 11.Ducts R ft2 <br /> I 7. Windows(250.0 sqft.) Description Area a.Sup:Attic, Ret:2nd Floor,AH:2nd Floor 6 261 <br /> a. U-Factor: Dbl,U=0.34 210.00 ftz " <br /> SHGC: SHGC=0.31 <br /> b. U=Factor: Dbl,U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 <br /> c. U-Factor: N/A ftz <br /> SHGC• " 13. Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 41.0 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.692 ft. <br /> Area Weighted Average SHGC: 0.315 14.Hot water systems <br /> a. Electric Cap:50 gallons <br /> S. Floor Types (1541.0 sqft.) Insulation Area <br /> a.Slab-On-Grade Ed e Insulation R=0.0 1104.00 ftz EF.0.950 <br /> 9 b. Conservation features <br /> b. Raised Floor R=19.0 437.00 ftz None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Total Proposed Modified Loads: 78.62 n A�� <br /> Glass/Floor Area: 0.096 Total Baseline Loads: 79.15 �� f1 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �.�'�IiE37',��,� <br /> this caiculation are in compliance with the Florida Energy specifications covered by this = � p <br /> �i'% z°;` ,rt� <br /> Code. calculation indicates compliance � �,,, � -_ ,,.� �, <br /> lW. %Prip•'�'4` 0 <br /> with the Florida Energy Code. ti ffrr ,, `=;.,„ , ti, � ' <br /> PREPARED BY: �'Vfl�-�.,�,�... Before construction is completed " "' ..� _ <br /> DATE: io-3n-n this buildin will be ins ected for � �'�'�`� ,,.. <br /> 9 P t� �y�� ,d <br /> compliance with Section 553.908 * �' n ,� <br /> I hereby certify that this building, as designed,is in compliance Florida Statutes. .� ���,5 <br /> with the Florida Energy Code. D�� <br /> _ OWNER/AGENT: r�'�� ' � - BUILDING OFFICIAL: I <br /> DATE: J(����-- • � DATE: - � , <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as I <br /> certified factory-sealed in accordance with R403.2,2.1. . <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. <br /> 10/30/2017 12:34 PM EnergyGaugeC�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.