Laserfiche WebLink
Pro ect Summar Job: <br /> ' = wrightsoft� Entire House y Byte: o�t,o,zo,a <br /> Progressive Air Systems, Inc - , <br /> 5907 Dasher Ct,Port�Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 ' <br /> � , � • . -..� <br /> For: DR Horton � � � <br /> Lot 1 Blk 7 Silverado Ranch, Zephyrhills, FL <br /> Notes: <br /> � - • � • <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions . <br /> Outside db 40 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 30 °F Design TD 16 �F <br /> Daily range L, <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 16693 Btuh Structure 16219 Btuh <br /> Ducts 3619 Btuh Ducts 5114 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> none <br /> (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 20312 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 21334 Btuh <br /> Method SimPlified Latent Cooling Equipment Load Sizing <br /> Construction quality Semrtight <br /> Fireplaces 0 Structure 2231 Btuh <br /> Ducts � 646 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ftz 1647 1647 Equipment latent load 2877 Btuh <br /> Volume�ft3) 14494 14494 <br /> Air changes/hour 0.26 0.14 Equipment total load 24211 Btuh <br /> Equiv.AVF (cfm) 63 34 Req. total capacity at 0.75 SHR 2.4 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> . Trade CARRIER Trade CARRIER <br /> Model CH14NB030**""A �Cond CH14NB030''*#*A <br /> AHRI'ref Coil FB4CNP030 <br /> AHRI ref <br /> Efficiency - 8 HSPF Efficiency 11.5 EER, 14 SEER <br /> Heating input Sensible cooling 22500 Btuh <br /> Heating output 29600 Btuh Qa 47°F Latent'cooling 7500 Btuh <br /> Temperature rise 27 °F Total cooling. 30000 Btuh <br /> Actual air flow 1000 cfm Actual air flow 1000 cfm <br /> Air flow factor 0.049 cfm/6tuh Air flow factor • 0.047 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure � 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.88 � <br /> Capacity balance point=31 °F <br /> Backup: <br /> Input=6 kW, Output=21934 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - <br /> .�. - -�d- wrightsofr° 2017-0ct-30 10:57:19 <br /> �+- Right-Suite�Universal 2017 17.0.21 RSU25554 Pa <br /> �� ...on\Wrightsoft Files\Express homesWrla 4EAB.rup Calc=MJ8 House faces: W 9e� <br />