My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19396
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19396
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2018 11:06:40 AM
Creation date
9/24/2018 11:06:38 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
18-19396
Building Department - Name
MCGOUGH III,WILLIAM G
Address
5045 19TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- � �. . / � :: �� <br /> Gulf�����d���9 <br /> �?, �. x�;�: ��_ <br /> � �� � e s o � D � s n"o � e ar-`�'����� .� <br /> �"'"�i;;,�, SUPPLY & MANUFAC�TURING <br /> ��� ::.t:r--�-;. <br /> � F._ x"�'a^.� ��t .t� <br /> � � �-:n��;�' ��:. _��:; <br /> �. �;� ;;-�"` ,.. <br /> � 4, ;�x�;:,;, <br /> , ti�'f ,�. <br /> �' ' � • C '` "� • • 1 <br /> ,� r� <br /> � ...`� ��. • � , � � � � . � � ■ � • � • '. . ;• <br /> - � <br /> - 'T?..h <br /> Code Compliance: The product described herein has demonstrated compliance with the <br /> Florida Building Code�017, Sections 1504.3.2. <br /> Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load <br /> requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3. <br /> Performance Standards: The product described herein has demonstrated compliance with <br /> • UL 580-06-Test for Uplift Resistance of Roof Assemblies <br /> • UL 1897-12- Uplift Test for Roof Covering Systems. <br /> • FM 4471-199Z, Section 4.4 Foot Traffic Resistance Test <br /> Reference Data: 1. UL 580-94/1897-98 Uplift Test <br /> Force Engineering &Testing, Inc. (FBC Organization #TST-5328) <br /> Report No. 117-0033T-05 & 1 17-0331T-08D, Dated 05/05/05 &07/09/08 <br />� 2. FM 4471-95, Section 4.4 Foot Traffic Resistance Test <br /> Force Engineering &Testing, Inc. (FBC Organization #TST-5328) <br /> Report No. 117-0238T-09E, Dated 0721/2009 <br />� 3. Certificate of Independence <br /> By Dan Kuhn, P.E. (FL#75519)@ Kuhn Engineering, LLC <br /> (FBC Organization #ANE ID 10743) <br /> Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. <br /> 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test <br /> standard. <br /> 3. The FM 4471-95 test standard is equivalent to the FM 4471-199Z test <br /> standard. <br /> Quality Assurance Entity: The manufacturer has established compliance of roof panel products in <br /> accordance with the Florida Building Code and Rule 61 G20-3.005(3)for <br /> manufacturing under a quality assurance program audited by an approved quality <br /> assurance entity. <br /> Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including <br /> Section 1507.4.2 and in accordance with Manufacturers recommendations. For <br /> slopes less than 3 12, lap sealant must be used in the panel side laps. <br /> Installation: Install per Manufacturer's recommended details. <br /> Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1. <br /> FL#11651.26 R3•OCTOBER 5,2017 <br /> s u � � ' � � � o � m <br /> � , II <br /> 11 •�' ' � • i � • � • 1'�' <br />
The URL can be used to link to this page
Your browser does not support the video tag.