Laserfiche WebLink
- I <br /> ' FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: P296 Builder Name: Marsella C_nstructign Inca e!/� <br /> Street: 5526 12th St Permit Office: <br /> City,State,Zip: Zephyrhills,FL,33542 Permit Number: cG� <br /> Owner: Marsella Construction Inc. Jurisdiction: <br /> Design Location: FL, Lakeland County:: Pasco Flo rida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1792.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=6.0 1493.30 ft2 <br /> b.Frame-Wood,Adjacent R=13.0 298.67 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (1775.0 sqft.) Insulation Area a.Under Attic(Vented) R=38.0 1775.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1775 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 11. Duct <br /> c. R= ft2 <br /> s R ft2 <br /> 7. Windows(177.6 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 360 <br /> a. U-Factor: Dbl,U=0.40 177.58 ft2 <br /> SHGC: SHGC=0.25 <br /> b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: a.Central Unit 34.5 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 33.0 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 3.116 ft. <br /> Area Weighted Average SHGC: 0.250 14.Hot water systems <br /> 8. Floor Types (1775.0 sqft.) Insulation Area a. Electric Cap:50 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1775.00 ft2 b. Conservation features EF:0.945 <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits CF,Pstat. <br /> Glass/Floor Area: 0.100 Total Proposed Modified Loads: 55.39 PASS <br /> Total Baseline Loads: 59.50 <br /> I hereby certify that the plans and specifications covered by Review of the plans andTKE <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: Navarrete Drafting Inc. Before construction is completed <br /> DATE: 04/28/17 this building will be inspected for <br /> compliance with Section 553.908 <br /> .r._ <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. f,� ��- <br /> with the Florida Energy Code. D <br /> OWNER/AGENT: BUILDING OFFI AL: <br /> DATE: DATE: r <br /> i <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> 4/28/2017 12:06 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />