Laserfiche WebLink
Manual J Summer Calculations <br /> Residential Load - Component Details (continued) <br /> Marsella Construction Inc. Project Title: Climate:FL_LAKELAND_LINDER_RGN <br /> 5526 12th St P296 <br /> Zephyrhills, FL 33542 <br /> 4/28/2017 <br /> WHOLE HOUSE TOTALS <br /> Sensible Envelope Load All Zones 10813 Btuh <br /> Sensible Duct Load 5727 Btuh <br /> Total Sensible Zone Loads 16540 Btuh <br /> Sensible ventilation 590 Btuh <br /> Blower 0 Btuh <br /> Whole House Total sensible gain 17130 Btuh <br /> Totals for Cooling Latent infiltration gain (for 48 gr. humidity difference) 0 Btuh <br /> Latent ventilation gain 973 Btuh <br /> Latent duct gain 1388 Btuh <br /> Latent occupant gain (4.0 people @ 200 Btuh per person) 800 Btuh <br /> Latent other gain 2750 Btuh <br /> Latent total gain 5911 Btuh <br /> TOTAL GAIN 23040 Btuh <br /> EQUIPMENT <br /> 1. Central Unit # 34500 Btuh <br /> *Key: Window types(Panes-Number and type of panes of glass) <br /> (SHGC-Shading coefficient of glass as SHGC numerical value) <br /> (U-Window U-Factor) <br /> (InSh-Interior shading device:none(No),Blinds(B),Draperies(D)or Roller Shades(R)) <br /> - For Blinds:Assume medium color,half closed <br /> For Draperies:Assume medium weave,half closed <br /> For Roller shades:Assume translucent,half closed i <br /> (IS-Insect screen:none(N),Full(F)or Half('/.)) <br /> (Omt-compass orientation) <br /> Version 8 <br /> EnergyGauge®/USRCZB v5.0 Page 3 <br />