Laserfiche WebLink
Jet StrecmO% Ultra Blowing Wool Insulation kNA� LTI <br /> Attie and Cavity Wall Card i �iwre fo lave �i <br /> Batts and Blankets Equipment Required <br /> When installed in accordance with the manufacturer's It is recommended that a pneumatic blowing machine and a corrugated hose with a minimum internal corrugation,a minimum length <br /> recommendations,Knauf Insulation batts and blankets will of 150'.Coils in the hose should not be less than 36"in diameter.Acceptable material feed rate is 5-35 lbs/minute.Recommended feed <br /> provide the full R-value. rate is 15-25 lbs/minute. <br /> R-value* Minimum Thickness Thermal Performance(Sidewall and Attic Application) <br /> To obtain an The staled thermal resistance(R-value)is provided by installing in accordance with the manufacturer's instructions.Failure to install the <br /> insulation resistance Installed insulation should required number of bags per 1,000 square feet and exceeding the maximum square feet of coverage per bag as recommended by the label <br /> (R-Value)of: not be less than: will result in lower installed R-values.Field blending of this product with other loose fill insulations is not recommended by the manufacturer. <br /> R-49 13.75" Cavity Wall Bag Net Weight-Nominal 32 Ibs.,Minimum 31 Ills. <br /> R-38HD 10.25' <br /> R-38 12.00" R-Value* Bags per 1000 SF Maximum Net Minimum <br /> R 30HD 8.25° To obtain an The number of bags Coverage per Bag Weight per SF <br /> insulation per 1,000 square feet Contents of this The weight per square <br /> R-30 10.00" Cavity resistance of net area should not bag should not feel of installed insulation <br /> R-26 9.00" Framing Depth of: Density be less than: cover more than: should not be less than: <br /> R-22 6.50" 2"x 4" 3.50" R-15 1.8 lbs./cu.ft. 16.4 bags 61.0 sq.ft. 0.525 lbs. <br /> R-21HD 5.50" 2"x 6" 5.50" R-23 1.8 lbs./cu.ft. 25.8 bags 38.8 sq.ft. 0.825 lbs. <br /> R-19 6.25"" <br /> R-15HD 3.50" 2"x 8" 7.25" R-31 1.8 lbs./cu.ft. 34.0 bags 29.4 sq.ft. 1.088 lbs. <br /> R-13 3.50" 2"x 10" 9.25" R-39 1.8 lbs./cu.ft. 43.4 bags 23.1 sq.ft. 1.388 lbs. <br /> R-11 3,50" R means resistance to heal flow.The higher the R-value,the greater the insulating power.To gel the marked R-value,it is essential that this insulation be installed property.. <br /> R-8 2.50" ' <br /> R-10 in a 5.5'cavity.Conforms toASTM C 62.and Federal Open Attic Application Bag Net Weight-Nominal 32 lbs.,Minimum 31 lbs. <br /> Specification HH-1-521F. Minimum <br /> Bags/ Maximum Minimum Initial Settled <br /> Framing Adjustment 1,000 SF Coverage Weight Installed Thickness** <br /> To compensate for framing members,the number of bags per The number of bags/ Contents of this The weight/SF Thickness Contents of this <br /> 1,000 sq.ft.of area to be insulated should be as shown below. R-Value* 1,000 SF of net area bag should not of installed Installed insulation bag should <br /> Ba s/MSF Ba s/MSF To obtain an insulation should not be less cover insulation should not should not be less not cover more <br /> 9 9 Framing <br /> Framing <br /> ming Framing <br /> resistance(R-Value)of: than: more than: be lessthan than: than: <br /> R-Value Dimensions Fra <br /> Joist O.C. O.C. R-60 29.7 33.6 SF .9521bs. 1 19.750" 19.750" <br /> 2x4 29.2 29.4 R-49 23.5 42.5 SF .753 lbs. 16.375" 16.375" <br /> R-60 2x6 28.9 29.1 R-44 20.9 47.8 SF .670 lbs. 14.875" 14.875" <br /> 2x8 28.6 28.9 R-38 17.8 56.2 SF .569 lbs. 13.000" 13.000" <br /> 2x4 23.0 23.2 R-30 13.6 73.3 SF .437 lbs. 10.375" 10.375" <br /> R-49 2x6 22.7 22.9 R-26 11.8 85.0 SF .377 lbs. 9.125" 9.125" <br /> 2x8 22.4 22.7 R-22 9.8. 102.2 SF .313 lbs. 7.750" 7.750" <br /> 2x4 20.4 20.6 <br /> R-44 2x6 20.1 20.3 R-19 8.4 119.3 SF .268 lbs. 6.750" 6.750" <br /> 2x8 19.8 20.1 R-13 5.7 175.3 SF .183 lbs. 4.750" 4.750" <br /> 2x4 17.3 17.4 R-11 4.7 210.8 SF .152 lbs. 4.000" 4.000" <br /> R-38 2x6 17.0 17.2 <br /> Bag Net WeghhNominal321bs.,Minimum 31 @s. <br /> 2x8 16.7 17.0 Coverage and installation data were detemuned using a Volu-Matic"II blwring machine in thud gear with 13'gale opening,2 0 pin air pressure and 150'of T intemaly-conugated hose. <br /> This product conforms to the performance requirements of ASTM C 764.Type I,and cancelled Federal Specificetion HH-1-1030B,Type 1,Class B.R-values are delermined in amordance with C 687 and C 518. <br /> 2x4 13.2 13.3 "W means resistance to heat lbw The higher the R-value,the greater the insulating power.To gel the marked R-value,it is essential that this insulalwn be installed pmpedy.II you do it yourself,gel ins8uc. <br /> R-30 2x6 12.9 13.1 bons and foflm the 'fully.InstruUmns do not ceme oath this package. <br /> "Based on Third Party 2-year settling study,the predicted settlement over a 20-year period would be 1 percent or less This amount of settling is thermally insignificant Therefore,the installed and settled <br /> 2x8 12.6 12.9 thicknesses are effectively the same. <br /> 2x4 11.3- 11.4 VoluWabeil is a registered trademark of Unisul. <br /> R-26 2x6 11.0 11.2 Builder's Insulation Statement <br /> 2x8 10.8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of... <br /> 2x4 9.3 9.5 &Value Thickness <br /> R-22 2x6 9.1 9.3 Attic Area R- at 'L_ Inches <br /> 2x8 8.8 9.1 Sloped Ceilings R- at Inches <br /> 2x4 7.9 8.1 Walls R- at Inches <br /> R-19 2x6 1 7.7 7.9 <br /> 2x8 7.4 7.7 Floors(over an unheated crawl space) R at Inches <br /> 2x4 5.3 5.4 Crawl Space Perimeter R- at Inches <br /> R-13 2x6 5.0 5.2 Date Installed '' r <br /> 2x8 4.8 5.0 Blown insulation has been installed in conformance with the above recomintleftdations to provide an R-value of: <br /> 2x4 4.3 4.4 R- using bags of this insulation to cover �-�-' square feet of area <br /> R-11 2x6 4.1 4.3 mi ' m thick inches. <br /> 2x8 3.8 4.1 <br /> UL Environment In n�oJnba`ctor ure) <br /> GREENGUARD Geld- <br /> - <br /> Kneuf Inrul°iion!,.Udin rnmlmmn.chi-d Company Dale <br /> U1 Emimnmem GREENGUARD Gold end i" <br /> U1 Enrironmem v°lidmad.be Iormoldnhyde Ire° <br /> UL Envimnment GREENGUARD Home Builder(signature) <br /> 0 Certincvlion Program- <br /> Pmd-ore con W w U1 Emuoemem <br /> GREENGUARD°onderdr cur 1 chemiml Company Dale <br /> o mdmr nir dud,prod..urnae. <br /> For more inbrm°tion,Wit./.corn/BB� <br /> The coverage information on this Attic/Sidewall card applies to the entire United States(including Minnesota). <br /> wwwAnaufinsulatiogrl Knauf Insulation,Inc. One Knauf Drive,Shelbyville,IN 46176 Tel:(800)825-4434 ext.8300 FAX:(317)398-3675 <br /> ©2015 Knauf Insulation,Inc. <br /> E <br />