Laserfiche WebLink
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Ryman 6 Plex Builder Name: <br /> Street: Permit Office: Pasco <br /> City,State,Zip: Dade City,FL, Permit Number: <br /> Owner: Ryman 6 Plex Jurisdiction: <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2 <br /> 1. New construction or existing New(From Plans) 9. Wall Types(4626.0 sqft.) Insulation Area <br /> -2.-Single-family-or-multiple-family-----------Multi=family-- -a.Concrete Block-Int Insul,Exterior R=5.0 3114.00 ft' <br /> Y-Fta-m-e--Wo-0-d-,Adjacent-------R=1,1- <br /> .0--1-512.00t2- <br /> 3. Number of units,if multiple family I c.N/A R= ft2 <br /> 4. Number of Bedrooms 12 d.N/A R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types(6576.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 6576.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 6576 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(522.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 200 <br /> a. U-Factor. Dbl,U=0.30 522.00 ft2 <br /> SHGC: SHGC=0.26 <br /> b. U-Factor. N/A ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: a.Central Unit 106.2 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor. N/A ft2 a.Electric Strip Heat 106.2 COP:1.00 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.000 ft. <br /> Area Weighted Average SHGC: 0.260 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (6576.0 sqft.) Insulation Area EF:0.95 1 0 <br /> a.Slab-On-Grade Edge Insulation R=0.0 6576.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 16.Credits Pstat Glass/Floor Area: 0.079Total Proposed Modified Loads: 166.75 <br /> Total Baseline Loads: 170.26 PASS <br /> I hereby certify that the plao add pecfications covered by Review of the plans and <br /> this calculation are in c6m <br /> 1 -ph3hce�,�th ihe Florida Energy specifications covered by this 0 Ap Off,Code. <br /> calculation indicates compliance <br /> With the Florida Energy Code. <br /> PREPARED BY: Before construction is completed <br /> DATE: this building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes, <br /> with the Florida Energy Code. Cps wt IT <br /> OWNER/AGENT: BUILDIN =OF IC <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> .certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report In accordance with R402A.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 9/7/2017 7:49 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1of4 <br />