My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19006
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 8:43:16 AM
Creation date
1/31/2019 8:43:13 AM
Metadata
Fields
Template:
Building Department
Company Name
DRIFTWOOD
Building Department - Doc Type
Permit
Permit #
17-19006
Building Department - Name
RYMAN CONSTURCTION
Address
6768 BASSWOOD CIRCLE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014 <br /> WALLS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar Below <br /> - V# Ornt----To.-WaII-Type -R--Value-F-t-In-F-t-In-Area-R--Valup Fraction-Absor-Grade%- <br /> I N Exterior Concrete Block-Int Insul Main 6 162 0 9 0 1458.0 ftz 0 0 0.8 0 <br /> 2 E Exterior Concrete Block-Int Insul Main 5 47 0 9 0 423.0 ft2 0 0 0.8 0 <br /> 3 S Exterior Concrete Block-Int Insul Main 5 90 0 9 0 810.0 ft2 0 0 0.8 0 <br /> 4 W Exterior Concrete Block-Int Insul Main 5 47 0 9 0 423.0 ft2 0 0 0.8 0 <br /> 5 Garage Frame-Wood Main 11 168 0 9 0 1612.0 ft2 0 0.25 0.8 0 <br /> DOORS <br /> V # Ornt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> S Wood Main None .39 18 7 126ft2 <br /> 2 Wood Main None .39 17 6 7 122.5 ft2 <br /> WINDOWS <br /> Orientation shown is the entered,Proposed orientation. <br /> Wall Overhang <br /> Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening <br /> I n I Metal Low-E Double Yes 0.3 0.26 120.0 It' I ft0in I ft0in Drapes/blinds None <br /> 2 n I Metal Low-E Double Yes 0.3 0.26 252.0 ft2 1 ft0in 1 ft0in Drapes/blinds None <br /> 3 e 2 Metal Low-E Double Yes 0.3 0.26 15.0 ft' I ft 0 in I ft0in Drapes/blinds None <br /> 4 s 3 Metal Low-E Double Yes 0.3 0.26 120.0 ft' I ft 0 in I ft 0 in Drapes/blinds None <br /> 5 W 4 Metal Low-E Double Yes 0.3 0.26 15.0 ft' I ft 0 in I ft 0 in Drapes/blinds None <br /> GARAGE <br /> V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 382.8 ft2 384 ft2 64 ft 8ft 1 <br /> INFILTRATION <br /> Scope Method SLA CFM 50 ELA Eql-A. ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000254 4384 240.68 452.63 .1906 5 <br /> HEATING SYSTEM <br /> V # System Type Subtype Efficiency Capacity Block Ducts <br /> I Electric Strip Heat None COP:1 106.2 kBtu/hr I sys#1 <br /> COOLING SYSTEM <br /> # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts <br /> 1 Central Unit Split SEER:14 106.2 kBtu/hr 3186 cfm 0.8 1 sys#1 <br /> 917/2017 7:49 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.