My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19006
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 8:43:16 AM
Creation date
1/31/2019 8:43:13 AM
Metadata
Fields
Template:
Building Department
Company Name
DRIFTWOOD
Building Department - Doc Type
Permit
Permit #
17-19006
Building Department - Name
RYMAN CONSTURCTION
Address
6768 BASSWOOD CIRCLE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job: Ryman 6 Plex <br /> ft wrightso , Project Summary Date: Sep O6,2017 <br /> Unit 6 By: DJM <br /> Pe6jbdt,M46Miatl6d <br /> For: Ryman 6 Plex <br /> Dade City,FL <br /> Notes: <br /> irma ilon, <br /> Weather: Tampa Intl AP,FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 43 *F Outside db 91 *F <br /> Inside db 70 *F Inside db 75 *F <br /> Design TD 27 oF Design TD 16 'F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 10083 Btuh Structure 10451 Btuh <br /> Ducts 2317 Btuh Ducts 3367 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 12400 Btuh Use manufacturers data n <br /> Rate/swing multiplier 0.96 <br /> Infiltration Equipment sensible load 13321 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Average <br /> Fireplaces 0 Structure 2570 Btuh <br /> Ducts 767 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2) 1108 110 Equipment latent load 3337 Btuh <br /> Volume(ft?) 9693 9693 <br /> Air changes/hour 0.43 0.23 Equipment Total Load(Sen+Lat) 16658 Btuh <br /> Equiv.AVF(cfm) 70 37 Req.total capacity at 0.80 SHR 1.4 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Make Carrier <br /> Trade 5 KW Trade CARRIER AIR,CONDITIONING <br /> Model Cond 24ACB31BABN32 <br /> AHRI ref Coil FB4CNP018L <br /> AHRI ref 9859025 <br /> Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER <br /> Heating input 3.6 kW Sensible cooling 13680 Btuh <br /> Heating output 12409 Btuh Latent cooling 3420 Btuh <br /> Temperature rise 20 *F Total cooling 17100 Btuh <br /> Actual air flow 570 cfm Actual air flow 670 cfm <br /> Air flow factor 0.046 cfm/Btuh Air flow factor 0.041 cfm/Btuh <br /> Static pressure 0.53 in H2O Static pressure 0.53 in H2O <br /> Space thermostat Load sensible heat ratio 0.81 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> Right-SulteO Universal 201717.0.23 RSU1 1033 2017-Sep-07 08:16:11 <br /> 44351....Google DrivelDocurnentslSonny'skRyman 6 Ptex.rup Calc=Mis Front Door faces: E Page 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.