Single .Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall.be a minimum of 8"above the road elevation.-and an engineered site plan. . <br /> 2. Lots shall be graded to comply with R401:3 of the F.B.C. <br /> 3. ;Compaction test required if 24' or more of fill dirt.is brought in at anyone place <br /> 4. .Tie in survey required before pouring concrete.. <br /> .. <br /> 5. Driveways require a R.O.W. use permit. ;All.4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> T . ,All property markers shall be uncovered'and in at time of first inspection: <br /> 8. All A.D.A. requirements shall be met... <br /> 9. No electric,=plumbing, mechanical,.or framing shall be covered without an inspection and. <br /> approval first. . <br /> 10:.A1i Garages shall comply with section R302,6 of the F.B.C.'(Fire Separation): . <br /> 11. Appliances shall not be installed in.a location where subject to mechanical damage unless <br /> protected byapproved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3'of the F.B.C. <br /> 13. Foundation supports for A/C units shall.be raised at least 3" above finished grade. M1308.1 <br /> 14. Return air in all bedrooms. F.B.C. M16.20.4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 .of the F.B.C. <br /> 16,All glazing requirements are to be in accordance with R308.4 of the P.B.C. <br /> 17. All means of egress are to.be in accordance with R311.of the F.B.C. <br /> i s. `.`Green.gypsum board" shall not be used as a Backer in showers or tubs. R702:4:2.F:B.C: <br /> 19. Combination-type AFCI breakers are required at all.locations requiring an AFCI type breaker.. <br /> 20. Carbon:monoxide alarms will be required in new construction that uses fossil-burning.heating <br /> or appliances or an attached garage. They.shall be installed in accordance with the T.B.C. <br /> 21. All pliinibing, mechanical, and electrical,shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2008 N.E.C. Codes will be enforced. <br /> 23. Tamper- Resistant Receptacles in accordance with 406.11..of the 20.08 N.E.0 <br /> 22.. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure: <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 5 h Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2008)- <br />