Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY'CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation -Residential Performance Method <br /> Project Name: R0218059 -Units 1 t£4 Builder Name: Butterfield <br /> Street: Ross Prairie Loop Permit Office- City of Zephyrhi7is <br /> City,State,Zip: Zephyrhilis,FL,33542 Permit Number_11 7 Z f J G�'� CL�.y� -7 <br /> Owner Typical Quadplex Units 1 and 4 Jurisdiction: 6 1600 <br /> Ic <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or e)dsting New(From Plans) 9. Wall Types(1040.0 sgft) insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=5.0 834.67 ftz <br /> b.Frame-Wood,Adjacent R=13.0 205.33 ftz <br /> 3. Number of units,if multiple family 1 c.WA R= ftz <br /> 4. Number of Bedrooms 3 d.WA R= ftz <br /> 5. Is this a worst case? No 10.Ceiling Types(1434.0 sgfL) Insulation Area <br /> a.UnderAttic(Vented) R=38.0 1434.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 1434 b.WA R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.WA R= tl? <br /> 11.Ducts R ftz <br /> 7. Windows(137.0 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:Laundry 6 225 <br /> a. U-Factor. Dbl,U=0.40 137.00 ftz <br /> SHGC: SHGC=0.25 <br /> b. U-Factor. WA ftz 12.Cooling systems kBhdhr Efficiency <br /> SHGC, a.Central Unit 282 SEER:15.00 % <br /> c: U-Factor. WA ftz <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor. WA ftz a_Electric Strip Heat 17.1 COP:1.00 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.672 ft <br /> Area Weighted Average SHGC: 0250 14.Hot water systems <br /> 8. Floor Types (1434.0 sgfL) Insulation Area a_Electric Cap:40 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1434.00 ftz b. Conservation features ER 0.970 <br /> b.WA R= ftz None <br /> c.WA R= ftz 15.Credit CF,Pstat <br /> Glass/Floor Area: 0.096 <br /> Total Proposed Modified Loads: 45.64 DAQ� <br /> Total Baseline Loads: 45.93 <br /> hereby certify that the plans and specifications covered by Review of the plans and Cg114E&2'4� <br /> this calculation are in compliance with the Florida Fite p Energy specifications covered by this _ � �0 <br /> Code. ` calculation indicates compliance <br /> with the Florida Energy Code, <br /> PREPARED BY: Before construction is completed �,� <br /> 02-08-18 E ..fI <br /> DATE: this building will be inspected for iil ,, <br /> compliance with Section 553.908 ti�A tz <br /> I hereby certify that this building,as designed,is in compliance Florida Statutes. - <br /> with the Florida Energy Code. Ca m <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-seated in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.&I.1 and this project:requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R407-4.1.2). <br /> 21812018 327 PM EnergyGaugeO USA-FlaRes2017 Section R4054.1 Compriant Software Page 1 of <br />