Laserfiche WebLink
Manual S Compliance Report: Job: R0218058 <br /> d- wrightsoW p p Date: 02-06-18 <br /> Entire House = By: TMN <br /> Bahr's Propane Gas &AC Inc <br /> 4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013 <br /> Project • • <br /> For: "Typical' Quadplex Units 1 and 4 <br /> Ross Prairie Loop, Zephyrhills, FL 33542 <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 20901 Btuh Entering coil DB: 79.2°F <br /> Outdoor design WB: 77.2°F Latent gain: 4894 Btuh Entering coil WB: 64.4°F <br /> Indoor design DB: 75.0°F Total gain: 25795 Btuh <br /> Indoor RH: 50% Estimated airflow: 1000 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split AC <br /> Manufacturer: Tempstar or Eqv. Model: TSA530GKA+EA*4X30L <br /> Actual airflow: 1000 cfm <br /> Sensible capacity: 21150 Btuh 101% of load <br /> Latent capacity: 7050 Btuh 144% of load <br /> Total capacity: 28200 Btuh 109% of load SHR: 75% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 42.9°F Heat loss: 15262 Btuh Entering coil DB: 66.97 <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 261 cfm <br /> Output capacity: 5.0 kW 112% of load Temp. rise: 59 OF <br /> Meets all requirements ofACCA Manual S. <br /> "wrigtmsafir 2018-Feb-08 12:52:59 <br /> Right-Suite®Universal 2018 18.0.10 RSU07440 Page 1 <br /> ACCA...-North Orientation\R0218059 -Units 1&4.rup Calc=MJ8 Building Front faces: N <br />