Laserfiche WebLink
AL Right-J®Worksheet Dab: R 88 <br /> Enure House Date: o2-06-1-os-,s <br /> By: TMN <br /> Bahr's Propane Gas &AC Inc <br /> 4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013 <br /> 1 Room name Entire House Master Bedroom <br /> 2 Exposed wall 104.3 ft 22.7 ft <br /> 3 Room height 8.0 ft d 8.0 ft heat/cool <br /> 4 Room dimensions 14.7 x 15.0 ft <br /> 5 Room area 1435.0 ftz 220.0 ftz <br /> Ty Construction U-value Or HTM Area (ftz Load Area (ftz Load <br /> number (Btuh/ft?°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) <br /> Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool <br /> 6 13A-5ocs 0.125 n 3.39 2.47 136 96 325 237 0 0 0 0 <br /> �C 4A5-2ob 0.540 n 14.63 12.27 20 0 293 245 0 0 0 0 <br /> L-D 11NO 0.350 n 9.48 10.83 _ 20 20 191 218 0 0 0 0 <br /> 13A-5ocs 0.125 a 3.39 2.47 469 394 1336 974 64 64 217 158 <br /> 11 4A5-2ob 0.540 a 14.63 30.30 15 0 220 454 0 0 0 0 <br /> 4A5.2ob 0.540 a 14.63 30.59 60 0 878 1835 0 0 0 0 <br /> w 13A-5acs 0.125 s 3.39 2.47 229 167 567 413 117 87 296 216 <br /> 4A5-2ob 0.540 s 14.63 12.27 12 12 176 147 0 0 0 0 <br /> 4A5-2ob 0.540 s 14.63 12.48 30 25 439 374 30 25 439 374 <br /> 11NO 0.350 s 9.48 10.83 20 20 191 218 0 0 0 0 <br /> R 12C-0sw 0.091 - 2.47 1.46 187 169 417 247 0 0 0 0 <br /> _D 11NO 0.350 n 9.48 10.83 18 18 169 194 0 0 0 0 <br /> C 16B-30ad 0.032 0.87 _ 1.74 1435 1435 1244 2500 220 220 191 383 <br /> F 22A-tpl 0.989 26.80 0.00 1435 104 2796 0 220 23 608 0 <br /> 6 c)AED excursion 226 -20 <br /> Envelope loss/gain 9240 8282 1750 1112 <br /> 12 a) Infiltration 2566 794 557 172 <br /> b) Room ventilation 0 0 0 0 <br /> 13 Internal gains: Occupants @ 230 4 920 2 460 <br /> Appliances/other 3200 0 <br /> Subtotal(lines 6 to 13) 1 11806 13196 2307 1744 <br /> Less external load 0 0 0 0 <br /> Less transfer 0 0 0 0 <br /> Redistribution 0 0 0 0 <br /> 14 Subtotal 11806 13196 2307 1744 <br /> 15 Duct loads 29% 48% 3456 6289 29% 48% 676 831 <br /> Total room load 15262 19485 2983 2575 <br /> Air required(cfm) 261 1000 51 132 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> -PI1 wrlgi atsaft-�� ^•'•••- -•�•--^•^--• Right-Suite®Universal 2018 18.0.10 RSU07440 2018-Feb-08 12:52:59Page 1 <br /> North Orientation\R0218059 -Units 1&4.rup Calc=MJ8 Building Front faces: N <br />