My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19461
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19461
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 9:48:08 AM
Creation date
1/31/2019 9:48:05 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19461
Building Department - Name
D R HORTON INC
Address
6526 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014. <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION , <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Hayden 2605 Elev C Builder Name: DRH Express Homes <br /> Street: (fc, 26 l�� rn_�/��I S� �� Permit Office: <br /> City,State,Zip: Zephyrhills, FL, / Permit Number: <br /> Owner: CSC t I �51 Jurisdiction: <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2614.2 sgft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood, Exterior. R=11.0 1285.30 ftz <br /> b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ftz <br /> 4. Number of Bedrooms 5 d.N/A R= ftz <br /> 10.Ceiling Types (1541.0 sgft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ft2 <br /> 6. Conditioned floor area above grade(ftz) 2605 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11. Ducts R ftz <br /> 7. Windows(250.0 sqft.) Description Area a.Sup:Attic, Ret:2nd Floor,AH:2nd Floor 6 261 <br /> a. U-Factor: Dbl,U=0.34 210.00 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl, U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 <br /> c. U-Factor: N/A ftz <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 4.1.0 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.052 ft. <br /> Area Weighted Average SHGC: 0.315 14.Hot water systems <br /> 8. Floor Types (1541.0 sgft.) Insulation Area a. Electric Cap:50 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ftz b. Conservation features EF:0.950 <br /> b.Raised Floor R=19.0 437.00 ftz None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.096 <br /> Total Proposed Modified Loads: 78.45 PASS <br /> SS <br /> Total Baseline Loads: 79.15 /`� <br /> I hereby certify that the plans and specifications covered by Review of the plans and -&'SHE SF <br /> this calculation are in compliance with the Florida Energy specifications covered by this =_ 0 <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: L ri4-SQ„ Before construction is completed r <br /> DATE: -g-t7 this building will be inspected for 0I :" ,ie <br /> compliance with Section 553.908 <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. j <br /> with the Florida Energy Code. ,,� �'OD WE <br /> OWNER/AGENT: -- /vim/` BUILDING WFA <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler Enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803•of RESNET Standards,is not greater than 0.060 Qn for whole house. <br /> 1 1/9/201 7 9:11 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.