My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19461
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19461
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 9:48:08 AM
Creation date
1/31/2019 9:48:05 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19461
Building Department - Name
D R HORTON INC
Address
6526 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: <br /> - - Wrlghtsoft® p p - Date: oCt 10,2014 <br /> Entire House By: <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> Proect Information, <br /> For: DR Horton/Express <br /> Lot 15 Blk 6 Silverado Ranch, Zephyrhills, FL <br /> • • • • • <br /> Design'Conditions <br /> Outdoor design DB: 91.2°F Sensible gain: 29932 Btuh Entering coil DB: 76.4°F <br /> Outdoor design WB: 77.1 OF Latent gain: 4144 Btuh Entering coil WB: 63.2°F <br /> Indoor design DB: 75.0°F Total gain: 34075 Btuh <br /> Indoor RH: 50% Estimated airflow: 1367 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042 <br /> Actual airflow: 1367 cfm <br /> Sensible capacity: 32445 Btuh 108%of load <br /> Latent capacity: 6269 Btuh 151%of load <br /> Total capacity: 38714 Btuh 114%of load SHR: 84% <br /> Heatir)g Ouipment, <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 27149 Btuh Entering coil DB: 69.5°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042 <br /> Actual airflow: 1367 cfm <br /> Output capacity: 37299 Btuh 137%of load Capacity balance: 31 OF <br /> Supplemental heat required- 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1367 cfm <br /> Output capacity: 8.6 kW 108%of load Temp. rise: 18 OF <br /> Meets are all requirements of ACCA Manual S. <br /> wri htsoft3 2017-Nov-09 09:13:06 <br /> 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 <br /> ...\Wrightsoft Files\Express homes\Hayden-4EHB.rup Calc=MJ8 House faces:SW <br />
The URL can be used to link to this page
Your browser does not support the video tag.