Laserfiche WebLink
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE-FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance. Method <br /> Project Name: Hayden 2605 Elev D . Builder Name: DRH Express Homes <br /> Street: 3 i}�0 �11 �1 �' Permit Office: <br /> City,State,Zip: Zepnyrhills, FL,3351�� Permit Number: <br /> Owner: Jurisdiction:' <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing Now(From Plans) 9. Wall Types(2614.2 sgft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 '1285.30 ft2 <br /> b.Concrete Block-Int insul,Exterior R=4.1 996.67 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ft2 <br /> 4. Number of Bedrooms 5 d.N/A R= ft2 <br /> 10.Ceiling Types (1541.0 sgft.) Insulation Area <br /> 5. !s this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2605 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11. Ducts R ft2 <br /> 7. Wlndows(250.0 sgft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 <br /> a. U-Factor: Dbl, U=0.34 210.00 ft2 <br /> SHGC: SHGC=0.31 _ <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13. Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0" HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1,692 ft. <br /> Area Weighted Average SHGC: 0.315 14. Hot water systems <br /> 8. Floor Types (1541.0 sgft.) Insulation Area a.Electric Cap:50 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 EF:0.950 <br /> b. Conservation features <br /> b.Raised Floor R=19.0 437.00 ft2 None <br /> c.N/A R= ft2 15.Credits <br /> Pstat <br /> Total Proposed Modified Loads: 78.27 ���75 <br /> Glass/Floor Area: 0.096. Total Baseline Loads: 79.15 <br /> I hereby certify that the plans and specifications covered by Review of the plans and © � S7;4'�'�S <br /> this calculation are in compliance with the Florida Energy specifications covered by this a t . p <br /> Code. calculation indicates compliance f, ''� `z= <br /> with the Florida Energy Code. <br /> PREPARED BY: �' � Before construction is completed � c1s '' � _ <br /> DATE: it-II-t7 this building will be inspected for `7 =`V �. <br /> compliance with Section 553.908 <br /> i hereby certify that this building,as designed, is in compliance Florida Statutes. �5 <br /> with the Florida Energy Cod ]WE- <br /> OWNER/AGENT: -! -� BUILDING OFFICIAL: <br /> DATE: i(�I DATE: ?- <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as• <br /> certified factory-sealed in accordance with R403.2.2,1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested In accordance with Section 803 of RESNET Standards, is not greater than 0.060 On for whole house. <br /> 11/1.1/2017 1:00 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />