18-19463
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19463
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 9:51:08 AM
Creation date
1/31/2019 9:51:06 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19463
Building Department - Name
D R HORTON INC
Address
6613 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: <br /> - - wrightsoft� �` Date: Oct 10,2014 <br /> Entire House By: <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Gt,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAG033669 <br /> ! ! ! <br /> For: DR Horton/Express <br /> Lot 33 Blk 6 Silverado Ranch, Zephyrhills, FL <br /> Cooling, ! ! <br /> Design Conditions <br /> Outdoor design DB: 91:20F Sensible gain: 32517 Btuh Entering coil DB: 76.4°F <br /> Outdoor design WB: 77.1 OF Latent gain: 4144 Btuh Entering coil WB: '63.2°F <br /> Indoor design DB: 75.0°F Total gain: 36660 Btuh <br /> Indoor RH: 50% Estimated airflow: 1367 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042 <br /> Actual airflow: 1367 cfm <br /> Sensible capacity: 32445 Btuh 100%of load <br /> Latent capacity: 6269 Btuh 151%of load <br /> Total capacity: 38714 Btuh 106%of load SHR: 840/. <br /> pting"EqUipment <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 27149 Btuh Entering coil DB: 69.5°F <br /> Indoor design DB:. 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042 <br /> Actual airflow: 1367 cfm <br /> Output capacity: 37299 Btuh 137%of load Capacity balance: 31 OF <br /> Supplemental heat required: 0 Btuh Economic balance:. -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1367 cfm - <br /> Output capacity: 8.6 kW 108%of load Temp. rise: 18 OF <br /> Meets are all requirements of ACCA Manual S. <br /> htSOfI`1 2017-Nov-1113:01:20 <br /> W <br /> �. 9 Right-suites Universal 2017 17.0.21 RSU25554 Page 1 <br /> �� ...\Wrightsoft Files\Express homes\Hayden-4EHB.rup Calc=MJ8 House faces: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.