Laserfiche WebLink
Sine e Famil Dwe in <br /> g . <br /> Y g <br /> Plan-Review Comments <br /> 1: F.F.E. shall be a.minirnum of.8".above the r 'ad,elevation:and an engineered site plan. <br /> 2.. Lots shall be-graded to comply with R401.3 of the F.B:.C:.. = <br /> 3. :Compaction:tesi required if 24" or more:of fill dirt is.brought in at any one place. .' <br /> .4. Tie in survey-required before pouring concrete.. <br /> 5.: Driveways require a R.O.W. use permit:: All 4:sides of driveway thru the sidewalk shall have. <br /> expansion material. <br /> 6.. All setbacks.shall be'met.:. <br /> 7. All property markers shall be.uncovered and marked at time of first.inspection: <br /> X. :All A:D.A. requirements shall be met. . <br /> 9.:.No:electric;plumbing,mechanical, or Raining shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages shall:coimplymith:section R302;6:of the:F.B:C (Fire Separation).. <br /> 11. Appliances.shall not be installed in a location where subject to rriechariical-damage unless <br /> prote6ted:'by approved,barriers. M303'A of.the F.B.C. <br /> 12. Water heaters shall comply with section P607.3 of the F.R.C. <br /> 13. Foundation supports for.A/C units shall be raised at least 3'.' above finished grade, M1308.1. <br /> 14. Return air in All bedrooms.F.B.C. ,M,1620.4 <br /> 15:-Smoke detectors are to be installed in accordance:with R313:.1-of theT.B.C. <br /> 16.-All glazing requirements are.to be in accordance'with R308.4,of the F.B.C. <br /> 17. All means.of egress are to:be in accordance with R31 l of the F.B.G. :: <br /> 18. `.`Green gypsum board shall not be used:as.a backer-in:showe'rs or tubs. R702.4.2,F.B.C. <br /> 19. Combination-type AFCI breakers.are,required:at all locations requiring an AFCLtype breaker: <br /> 20: Carbon monoxide.alarms:will be required in.'new.construction that uses:fossil-burning heating : . <br /> :or appliances or an attached garage:. They shall be,installed in accordance with.the F.B.C.. <br /> 21. All plumbing,mechanical,:and electrical shall be separate from unit to:unit. This includes all. <br /> underground plumbing and electric: <br /> 22.:All 2008:N.E.'C: Codes:will be enforced.. <br /> 23.Tamper- Resistant Receptacles in accordance with 406.11-of the 2008 ME:C <br /> .24. In accordance..with the Laiid.Development Code;,lots.shall be.'sodded before final at least 10 <br /> feet`around the.structure: <br /> 25. A.eopV of the eherzy cacls shall be' with Oermit'at all tinres <br /> 26 Copy of final insulation report shall be.provided with.permit before.final <br /> F.F.E.-Finished Floor Elevation. <br /> F.B.C- <br /> Florida Building Code 5 'Edition <br /> R.O.W.-Right.of Way <br /> A.D.A.-Americans with Disabilities Act . N.E.C.-National Electric Code (2008): <br />