Laserfiche WebLink
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION , <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Hayden 2605 Elev D Builder Name: DRH Express Homes <br /> Street: beyu( WCyqa1-TraJ1t Permit Office: <br /> City,State,Zip: Zephyr ills,.FL, Permit <br /> Number: <br /> Owrier: Jurisdiction: <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2614.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=1 1.0 1285.30 ftz <br /> b.Concrete.Block-Int Insul, Exterior R=4.1 996.67 ft;! <br /> 3. Number of units,if multiple family I c.Frame-Wood,Adjacent R=1 1.0 332.22 ft2 <br /> 4. Number of Bedrooms 5 d.N/A R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (1541.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1541.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2605 b.N/A R= ft2 <br /> Conditioned floor area below grade(W) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(250.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 <br /> a. U-Factor: Dbl,U=0.34 210.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 40.0 SEERA4.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.692 ft. <br /> Area Weighted Average SHGC: 0.315 14.Hot water systems <br /> 8. Floor Types (1541.0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 b. Conservation features EF:0.950 <br /> b.Raised Floor R=19.0 - 437.00 ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Total Proposed Modified Loads: 78.66 <br /> Glass/Floor Area: 0.096 Total Baseline Loads: 79.15 PASS <br /> I hereby certify that the plans and specifications covered by Review of the plans and S_r <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> -Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: Before construction is completed FQ <br /> PATE: this building will be inspected for <br /> compliance with.Section 553.908 <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. <br /> with the Florida Energy C d9. 0. y It <br /> OWNER/AGENT: BUILDING OFFICIAL- <br /> I I--- <br /> DATE:.- DATE: 2:0- 7(z <br /> - Compliance requires certification by the air handier unit manufacturer that the air.handier enclosure qualifies as <br /> certified factory-sealed in accordance with R4012.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0,060 Qn for whole house. <br /> 1 1/11/20117 12:43 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />