My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19464
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19464
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 9:52:14 AM
Creation date
1/31/2019 9:52:11 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19464
Building Department - Name
D R HORTON INC
Address
6589 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Summary. Job: <br /> wrightsofto Date: Oct 10,2014 <br /> Entire House By: <br /> Progreigsive Air Systems, Inc <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC0336.69 <br /> I M1 . <br /> For: DR Horton/Express <br /> Lot 30 Blk 6 Silverado Ranch, Zephyrhills, FL <br /> Notes: <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 40 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 30 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 20520 Btuh Structure 23527 Btuh <br /> Ducts 6629 Btuh Ducts 8990 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 27149 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 32517 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2674 Btuh <br /> Ducts 1469 Btuh <br /> Central vent (O.cfm) 0 Btuh <br /> Heating coaling (none) <br /> Area(ft2) 2�"'51 26M Equipment latent load 4144 Btuh <br /> Volume(ft3) 22094 22094 <br /> Air changes/hour 0.22 0.11 Equipment total load 36660 Btuh <br /> Equiv.AVF (cfm) 81 41 Req. total capacity at 0.75 SHR 3.6 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NB042****A Cond CH14NB042****A <br /> AHRI ref Coll F134CNP042 <br /> AHRI ref <br /> Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER <br /> Heating input Sensible cooling 30750 Btuh <br /> Heating output .38500 Btuh Ca)47OF Latent cooling 10250 Btuh <br /> Temperature rise 26 'OF Total cooling 41000 Btuh <br /> Actu5I air flow 1367 cfm Actual air flow 1367 cfm-- <br /> Air flow factor 0.050 cfm/Btuh Air flow factor 0.042 cfm/Btuh <br /> Static pressure 0.56 in H2O Static pressure 0.56 in H2O <br /> Space thermostat Load sensible heat ratio 0.89 <br /> Capacity-balance point=31 OF <br /> Backup: <br /> Input=9 kW, Output= 29290 Btuh, 100 AFU E <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> wrightsoft, Right-SuiteD Universal 2017 17.0.21 RSU25554 '2017-Nov-11 12:44:32 <br /> Page 1 <br /> .�.\Wflghtsoft Files\Express homes\Hayden-4EHB.rup Calc=MJ8 House faces: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.