Laserfiche WebLink
S ing e Farri* Y Dwelling:. :. . <br /> planComments <br /> Review . <br /> l: F.F.E.; shall be a minimum of 8" above,the road.elevation;and an engirieered.site plan. : <br /> 2.. Lots shall be graded.to-comply with R401.3 of the F.B.C. .: <br /> 3. Compaction:test required if 24 or more.of fill dirt is.brought.in:at an:y one place: <br /> 4. :Tie in.survey required before pouring concrete. <br /> 5. Driveways:require a R.O.W. use permit.: All sides of driveway.thru the sidewalk shall-have. . <br /> expansion material:. . . <br /> 6. Ail.setbacks shall be met.: .' <br /> 7.: :All property'markers shall be,uncove'red and marked.at time"of first inspection: <br /> 8 .All A.D.A. requirements shall be met..'. <br /> 9. No:electric,plumbing,mechanical;"or framing shall be covered without an inspection and <br /> approval first..: <br /> 10. All Garages shall:comply.with.section R302.6 of the F.B:C;:(Fire S:eparation). <br /> 11.Appliances shall not:be installed in:a locationwhere subject to it chanical darnage unless..." <br /> protected by approved barriers. M303.4 of.'the F.B.C. <br /> 12. Water,heaters shall corriply:with section:P607.3 of.the F:B.C: <br /> 13. Foundation supports for,A/C.units shall be raised at least 3'' above finished grade,. M1308.1. <br /> 14. Return aif in all bedrooms.-F.B.C. M1620.4 <br /> 15: Smoke detectors'are.to be installed:in accordance with:R31'3.1 of ihe:F.B.C. <br /> .16::All glazing requirements are..to be in accordance with R308.4.of the.ERE. <br /> 17. All means.of egress are to be in accordance-with R3 I L of the R.B.C. <br /> 18. `.`Green gypsum.board'' shall not b 'used:as.a backer.in:showers:or tubs. R702.4:2 F.B.C. <br /> 19. Combination-fypeAFCI�breakers are.required.at all.locations requiring an AFCI,type breaker: <br /> 20. Carbon monoxide alarms:will be required in new-construction that uses fossil-biiming.heating <br /> :or appliances or an attached garage.. They shall be,installed in accordance with.the F.B.C. <br /> 21. All plumbing, mechani-al,.and electrical shall be'sepatate from unit to:unit: This includes all. .' <br /> underground plumbing and electric: <br /> M All 2008.N.E.C. Codes.will be enforced. <br /> 23.Tamper-Resistant Receptacles in accordance with 406.11 of the 2008 NRC <br /> 24::In accordance with the Land.Development.Code; lots.shall be sodded before final of least l 0 <br /> feet:around the structure: <br /> 25. A.copy of the ever y cacls shall be with pern:itat all ti�raes. <br /> :. '26"Copy oflinal insulation repbrt shall bevrbvided with.permit.before final <br /> F.F.E.-Finished Floor.Elevation <br /> F.B.C=Florida Building Code 5�':Edition <br /> R,O.W.-Right.of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric.Code (2008)- <br />