Laserfiche WebLink
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Neuville 1751 Elev D Builder Name: DRH Express <br /> Street: 6i5ol WDgcn 7rQ tl S�. Permit Office: <br /> City,State,Zip:l Zeph ills, FL,3��\ Permit Number: <br /> Owner: ✓ pal Jurisdiction: <br /> Design Location: FL,Tampa 2 t County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1640.9 sgft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1366.40 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 274.44 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (1751.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1751.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1751 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11. Ducts R ft2 <br /> 7. Windows(174.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 392 <br /> a. U-Factor: Dbl,U=0.34 134.50 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a. Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.110 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> a. Electric Cap:50 gallons <br /> 8. Floor Types (1751.0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1751.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.100 /'1�7CS <br /> Total Proposed Modified Loads: 59.60 PASS <br /> Total Baseline Loads: 60.20 <br /> 1 hereby certify that the plans and specifications covered by Review of the plans and sr41 ' <br /> this calculation are in compliance with the Florida Energy specifications covered by this 0° _ <br /> Code. calculation_indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: Before construction is completed w ' <br /> DATE: n-11-17 this building will be inspected for Ls;. <br /> compliance with Section 553.908 <br /> I hereby certify that this building, as designed,is in compliance Florida Statutes. <br /> with the Florida Energy Code. <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: DATE: 2-1 <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.060 On for whole house. <br /> 11/11/2017 1:32 PM' EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />