My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19465
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19465
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 9:53:07 AM
Creation date
1/31/2019 9:53:05 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19465
Building Department - Name
D R HORTON INC
Address
6581 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: <br /> -�- wrightsoft� p P Date: Sep 04,2015 <br /> Entire House By: <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:'727-847-3898 Fax:727-815-3399 License:CAC033669. <br /> Project • • <br /> For: DR Horton/Express <br /> Lot 29 Blk 6 Silverado Ranch, Zephyrhills, FL <br /> C66ling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.2°F Sensible gain: 21774 Btuh Entering coil DB: 76.1 OF <br /> Outdoor design WB: 77.1 OF Latent gain: 2957 Btuh Entering coil WB: 63.0°F <br /> Indoor design DB: 75.0°F Total gain: 24731 Btuh <br /> Indoor RH: 50% Estimated airflow: 1000 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Sensible capacity: 23399 Btuh 107%of load <br /> Latent capacity: 3923 Btuh 133%of load <br /> Total capacity: 27322 Btuh 110%of load SHR: 86% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 20877 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Output capacity: 25626 Btuh 123%of load Capacity balance: 31 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1000 cfm <br /> Output capacity: 5.8r kW 95%of load Temp. rise: 50 OF. <br /> Meets are all requirements of ACCA Manual S. <br /> .0 wri htsoft° 2017-Nov-1113:35:14 <br /> ^, 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 <br /> �� ...ightsoft Files\Express homes\Neuville-1751.rup Calc=MJ8 House faces: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.