Project Sum 117a1'y Date: Sep 04,2M <br /> - vvrightsoft® Entire House By-- <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> •]ect information <br /> For: DR Horton/ Express <br /> Lot 29 Blk 6 Silverado Ranch, Zephyrhills; FL <br /> Notes: <br /> Design Information <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 40 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 30 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 17189 Btuh Structure 16565 Btuh <br /> Ducts 3687 Btuh Ducts 5209 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 20877 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 21774 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2301 Btuh <br /> Ducts 656 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2) 1740 1740 Equipment latent load 2957 Btuh <br /> Volume(ft3) 15314 15314 <br /> Air changes/hour 0.26 0.14 Equipment total load 24731 Btuh <br /> Equiv.AVF(cfm) 66 36 Req.total capacity at 0.75 SHR 2.4 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NB030****A Cond CH14NB030****A <br /> AHRI ref Coil FB4CNP030 <br /> AHRI ref <br /> Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER <br /> Heating input Sensible cooling 22500 Btuh <br /> Heating output 29600 Btuh @ 47OF Latent cooling 7500 Btuh <br /> Temperature rise 27 OF Total cooling 30000 Btuh <br /> Actual air flow 1000 cfm Actual air flow 1000 cfm <br /> Air flow factor 0.048 cfm/Btuh Air flow factor 0.046 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.88 <br /> Capacity balance point=31 OF <br /> Backup: <br /> Input=6 kW, Output= 19779 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> wri htSOFt" 2017-Nov-1113:35:14 <br /> �� 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 <br /> ..ightsoft Files\Express homes\Neuville-1751.rup Calc=MJ8 House faces: E <br />