Laserfiche WebLink
Section . Plans Verified Field Verified <br /> #., Insulation Inspection'.; ..Complies? " .CommenWAssuMptions <br /> & Req.l Value: : Value <br /> D <br /> 5.4.3:1 ;Air sources of air-'leakage in the complies ;Requirement will be met. <br /> [IN111 building thermal envelope are �❑Does Not <br /> !sealed,caulked,gasketed, I - - <br /> weather stripped or wrapped with []Not Observable <br /> (moisture vapor-permeable 1❑Not Applicable <br /> ;wrapping material to minimize air ; <br /> leakage. y <br /> 5.5:3.1 Roof R-value. For some ceiling R- R- iRrComplies ;See the Envelope Assemblies <br /> [IN2]1 systems,verification may need to:❑ Above deck ;❑ Above deck ❑Does Not table for values. <br /> occur during Framing Inspection. ❑ Metal j❑ Metal ❑Not Observable <br /> ❑ Attic ❑ Attic L❑Not Applicable <br /> I <br /> 5.5.3.2 jAboye-grade wallinsulation.R- R- R ;❑Corriplies See the ErivelopeAssemblies <br /> 1 value. ;❑ ;table for values. <br /> [IN6] � ,❑ Mass ,El Does Not , <br /> ❑ Metal ❑ Metal ;❑Not Observable <br /> ❑ Steel ❑ Steel TXot Applicable <br /> ❑ Wood ;❑ Wood <br /> 5.8.1.2' ;Above-gi•ade.wall insulation Complies ;Requirement will.be met. <br /> [IN7]1 installed per manufacturer's j❑Does Not <br /> instructions. <br /> I❑Not Observable <br /> r <br /> 0NofApplicable . ;. <br /> ' R- Complies ;See'theEnvelope.Assemblies <br /> 5.5.3.4 ,Floor-insulation R-value. R- , <br /> [IN8]2 I ❑ Mass ❑ Mass ;❑Does Not table for values. <br /> i ❑ Steel ❑ Steel ;❑Not Observable <br /> I ❑ Wood ❑ Wood ❑Not Applicable <br /> I I <br /> 5.8.1.1 ;Building envelope insulation is ❑Complies ;Requirement will be met. <br /> [IN10]z labeled with R-value or insulation ❑Does Not <br /> certificate providing R-value and I <br /> ;other relevant data. i❑ Observable <br /> ,VNot Applicable <br /> 5.8.1.4 ;Eaves are baffled to deflect air to 1❑Complies ;Requirement will be met. <br /> [IN11]Z labove the insulation: `❑Does Not <br /> I �❑"Observable <br /> ,FeNotApplicable <br /> 5.8.1.5 Insulation is installed in . ,❑Complies Requirement will be met. <br /> [IN12]2 ;substantial contact with the I❑Does Not <br /> inside surface separating ❑ t Observable <br /> conditioned space from <br /> unconditional space. i._ Not Applicable ; <br /> 5.8.1.6 !Recessed equipment installed in 10Complies ;Requirement will be met: <br /> [IN13]2 i building envelope assemblies +❑Does Not <br /> does not compress the adjacent . j❑Not Observable <br /> insulation. <br /> Nit Applicab e <br /> o I <br /> 5.8.1.7 1Exterior insulation is:protected ❑Compli'es ;Requirement.will.be met. <br /> [IN14]2 ifrom damage with a protective ❑Does Not <br /> I material.Verification for'exposed J <br /> (foundation insulation may need ❑ t Observable <br /> to occur during Foundation Not Applicable <br /> ;.Inspection.. i <br /> 5.8.1.7.1 ;Attics and mechanical rooms ❑Complies ;'Requirement will be met. " <br /> [IN15]2 have insulation protected where .1❑Does Not <br /> adjacent to attic or equipment <br /> ;access. ,❑f at Observable <br /> �. jV'Not Applicable <br /> 1 H_igh impact(Tier 1) 2 I.Mediurp Impact(Tier 2),', 3 LOW Impact(Tier 3) <br /> Project Title: NWNA Zephyrhills Report date: 02/20/18 <br /> Data filename: C:\Users\wdrowlan\Desktop\NWNA-Zeph.cck Page 10 of 13 <br />