My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19501
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19501
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 10:10:10 AM
Creation date
1/31/2019 10:10:08 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19501
Building Department - Name
LENNAR HOMES LLC
Address
6671 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014 <br /> WINDOWS <br /> Orientation shown is the entered orientation => changed to Worst Case. <br /> Wall Overhang <br /> # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening <br /> 14 N=>NW 6 Metal Low-E Double Yes 0.56 0.28 23.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 <br /> 15 N=>NW 6 Metal Low-E Double Yes 0.56 0.28 17.7 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 <br /> 16 N=>NW 6 Metal Low-E Double Yes 0.56 0.28 12.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None <br /> 17 E=>NE 9 Metal Low-E Double Yes 0.54. 0.31 48.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None <br /> 18 W=>SW 8 Metal Low-E Double Yes 0.54 0.31 6.7 ft2 1 ft 0 in 0 ft 8 in None None <br /> 19 S=>SE 2 Metal Low-E Double Yes 0.54 0.31 23.0 ft2 1 ft 0 in 10 ft 4 in None None <br /> GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 722 ft2 722 ft2 61 ft 9.3 ft 1 <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000382 4265.1 234.15 440.35 .3525 7 <br /> HEATING SYSTEM <br /> # System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump None HSPF:8.5 21.8 kBtu/hr 1 sys#1 <br /> 2 Electric Heat Pump None HSPF:8.5 26 kBtu/hr 2 sys#2 <br /> COOLING SYSTEM <br /> # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts <br /> 1 Central Unit Split SEER: 16 25.2 kBtu/hr 756 cfm 0.85 1 sys#1 <br /> 2 Central Unit Split SEER: 15 30 kBtu/hr 900 cfm 0.85 2 sys#2 <br /> HOT WATER SYSTEM <br /> # System Type SubType Location EF Cap Use SetPnt Conservation <br /> 1 Electric None Garage 0.95 40 gal 60.9 gal. 120 deg None <br /> SOLAR HOT WATER SYSTEM <br /> FSEC Collector Storage <br /> Cert # Company Name System Model# Collector Model# Area Volume FEF <br /> None None ft2 <br /> I <br /> i <br /> 7/27/2017 2:42 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.