Laserfiche WebLink
Single Family Dwelling <br /> Plan - <br /> - an Review Comments <br /> L F.F.E. shall be a minimum-of.8".above the road elevation and an engineered site plan. . <br /> 2. -Lots shall be graded_to comply with R401.3 of the F.B.C: . <br /> 3.: Coinpaction-test req uired-if 24 or more of fill dirt is lirouglit in:at anyone place: :. <br /> 4. :Tie in survey required-before pouring concrete.. <br /> 5.. Driveways:require a-R:O.W. use permit:. All-4-sides of driveway thru the sidewalk shall have. <br /> expansion matenal..- <br /> 6.. All setbacks.shall be met.: <br /> 7.- ;All.property:markers shall be_uncovered and marked at time of first.inspection. <br /> .8. All A.D.A.-requirements shall be met. . <br /> 9.: No:electric;plumbing,mechanical;.or framing shall be covered without an,inspection and <br /> approval first. <br /> 10.All Garages shall:comply_with:section R302:6 of the.F.B.C.:.(Fire Separation).. <br /> I l.Appliances:shall not be installed in:a location where subject to mechanical damage unless <br /> protected-by approved barriers. M303.4 of-the F.B.C- <br /> 12. Water heaters shall comply with section P607,3 of the-F.R.C. <br /> I3..Foundatiori supports for-'A/C units shall-be raised at least 3" above finished grade.. M1308.1. <br /> 14. Return air in all.:bedrooms.-F.B.C. M1620.4. <br /> 15. Smoke detectors are fo be iristalled:in accordance:with"R313:1 of the F.B.C. <br /> 16:All glazing requirements are to be"in accordance with R308.4.of the F.B.C. <br /> 17. All means,of egress are to be in:accordance with R311:of the F.B.C. .: <br /> .. . <br /> 18. `.`Green gypsum.board shall not be used-as.a backer.in.showers:or tubs. R702.4.2.F.B.C. <br /> 19.'Combination-type AFCI breakers are,required at all.locations requiring an AFCI type breaker: <br /> 20. Carbon monoxide alarms:will be required in-new.construction that uses fossil-burning heating <br /> :or appliances or an attached garage:. They shall be installed in accordance'with.the V.B.C. <br /> 21. All plumbing, mechanical, and.el'e trical shall:be separate-from unit to.unit: This includes all. . <br /> underground:plunibingand electric. <br /> 22. All 2011:N:E:C: Codes will be enforced <br /> 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2011 N.E'C <br /> .24.:In accordance..with the Land.Development:Code,_lots shall be-sodded before final'at least 10. . <br /> feet:around the structure: <br /> 25 A copy of the enere.y cacls shall be with permit at all'iinaes <br /> 26. Copy of fnal.insulation report shall be.provided with.permit befve.flnaL <br /> F:F-E.=Finished Flo or.Elevation <br /> Florida Building Code 04 Edition <br /> R.O.W.-Right Of Way <br /> A.D.A.-Americans with Disabilities Act . N.E.C.-National Electric Code(2011) <br />