Laserfiche WebLink
f <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> 0305 <br /> Project Name: 2421 B sf ADS Buif8er Name: Lennar Homes <br /> Street: 6670 Paden Wheel Street Permit office: Pasco <br /> City,State,Zip: FL, Permit Number: <br /> Owner. Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2344.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.0 1874.90 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 469.69 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2421.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 2421.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2421 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(230.7 sgft.) Description Area a.Sup:Attic,Ret:dining rm,AH:laundry 6 484.2 <br /> a. U-Factor. Dbl, U=0.54 140.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor. Dbl,U=0.58 64.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 26.67 ft2 <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.283 ft. <br /> Area Weighted Average SHGC: 0.309 14.Hot water systems <br /> 8. Floor Types (2420.2 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 2420.20 ft2 b. Conservation features EF:0.950 <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.095 <br /> Total Proposed Modified Loads: 77.09 PASS <br /> Total Baseline Loads: 77.37 <br /> I hereby certify that the plans and specifications covered by Review of the plans and <br /> this calculation are in compliance with the Florida Energy specifications covered by this b Off„ <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: - Dave AupGh Before construction is completed r . <br /> DATE: this building will be inspected forf�Ji ;; <br /> compliance with Section 553.908 <br /> I herebycertify that this building,as designed,is in compliance Florida Statutes. <br /> fY 9� 9 p <br /> with the Florida Energy Code. G'O� <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 9/27/2017 6:52 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software _ Page 1 of 6 <br />