My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19509
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19509
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 10:16:36 AM
Creation date
1/31/2019 10:16:34 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19509
Building Department - Name
LENNAR HOMES LLC
Address
6614 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
KAMM <br /> When 13.11ding,TWk.W.I.it— <br /> ENERGY EFFICIENCY CODE FOR BUILDING <br /> CONSTRUCTION <br /> Envelope Leakage Test Report <br /> Prescriptive and Performance Method <br /> Project Name: /,,,07 Builder Name: L 6 <br /> Street: &/',/4 11JW60'-J TIOtIl— J Permit Office: <br /> City, State, Zip: PermItNumber, <br /> Design Location: Jurisdiction: <br /> Envelope Leakage Test Results <br /> Single Point Test Data: <br /> HOUSE PRESSURE: FLOW: — S <br /> Leakage Characteristics Pass Fail <br /> 121P <br /> ACH(50): 7�-40 S <br /> R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air <br /> changes per hour in Climate Zones I and 2 ...Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 <br /> Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals <br /> licensed as set forth in Section 489.105(3)(f), (g), or(I)or an approved third party.A written report of the results of the test shall be <br /> signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all <br /> penetrations of the building thermal envelope, <br /> 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other <br /> infiltration control measures; <br /> 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended <br /> Infiltration control measures; <br /> 3.Interior doors,If installed at the time of the test,shall be open; <br /> 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; <br /> 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and <br /> 6.Supply and return registers,If installed at the time of the test,shall be fully open <br /> I hereby certify that the above envelope leakage Where required by the code official, testing shall be <br /> performance results demonstrate compliance with conducted by an approved third-party. A written report of <br /> Florida Energy Code requirements in ccordance with the test results shall be signed by the third party <br /> 12 -7 " <br /> section R4024z7w conducting the test and provided to the code official. <br /> SIGNATURE: . <br /> PRINTED NAME: BUILDING OFFICIAL: <br /> DATE: '9 2/C-5 DATE: <br /> Testing was conducted In accordance with ANSIIRESNETACC 380 to meet the 2017 residential energy code. <br />
The URL can be used to link to this page
Your browser does not support the video tag.