Laserfiche WebLink
: Sin e Faml Dwe in. <br /> g Y g <br /> Plan Review Comments <br /> 1. F.F.B. shall be a:minimum:of.8" above.the road.elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply.with R401.3 of the-F.B.C. <br /> 3.: _Compaction test required if 24" or niore of fill dirt is brought in:at any one place. . <br /> 4:. Tie in-survey required before pouring concrete. <br /> :.-5. Driveways:require a R.O.W. use permit:. All 4:sides of driveway . <br /> thru the sidewalk shall have. <br /> expansion material:. : . <br /> 6- All setbacks shall.be met..7.. All.property markers-shall be uncovered and marked.at time of first.'inspection: <br /> 8:. :All A.D.A. requirements shall be met.: . <br /> 9. No:electric;plumbing,mechanical, or frainirig shall be covered without an:inspection and <br /> approval first.. . <br /> 10. All Garages shall;comply with.section R302:6.of the.F.B.C-:-(Fire Separation).. <br /> 11.Appliances:shall iiot.be installed in:a location where subject to mechanical damage unless <br /> protected by approved barriers: M303.4 of the F.B.C. <br /> 12. Water'heaters shall�com .l :with section::P607,3 of the F.R.C. <br /> pY <br /> 13.'Foundation supports for A/C.units shall be raised at least 3'.' above finished grade.. M1308.1 <br /> 14. Return air in'all bedroonis.T.B.C. .MI620.4 . . <br /> 15. Smoke detectors are-to be installed:in accordance with R31'3.1 of theT.B.C. <br /> 16:.All glazing requirements-are:to be in accordance with R308.4.of the.F.B.C. <br /> 17. All means.of egress are to:be in:accordaiice with R31 t of the F.B.C. <br /> 18. `.`Green gypsum board"shall notbe used:as.a backer.in showers or tubs.-R702.4.2 F.B.C. <br /> : 19. Combination-f ype AFCI breakers are required at all,locations requiring.an AFCLtype breaker: <br /> 20: Carbon monoxide,alarms'will be required in.new construction that uses fossil-burning heating <br /> or appliances or an attached garage: They shall be installed'in accordance with,the F.B.C: . <br /> 21. All plumbing,mechanical,:and_electrical shall:be separate from unit to unit. This includes all. <br /> underground plumbing-arid electric: <br /> 22. All 2011:N.E:C. Codes.will-be enforced: <br /> 23.Tamper'Resistant Receptacles-in accordance with 406.11 of the 2011 N.E.G <br /> .24. In accordance—With.the Land.Development:Code;_lots shall be.sodded before final at-least 10 . <br /> - feet.around the.structure: <br /> 25.A copy of the enemy caclssh'all be with:yern:itat all times. <br /> -26 Copy of final insulation report shall be provided with:pennit before.rMaL <br /> F.F.E...Finished Floor Elevation. <br /> F.B.0 Florida Building_Code 0 Edition <br /> ,O.W.-Right of Way <br /> A.D.A. Americans with Disabilities Act N.E.C.-National Electric Code(2011): <br />