Laserfiche WebLink
Building Analysis Job: 2575BI sf ADS <br /> Date: 2/112018 <br /> lower floor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Project Information <br /> For: Lennar Homes <br /> Design Conditions <br /> Location: Indoor: Heating Cooling <br /> Tampa International AP, FL, US Indoor temperature(*F) 70 75 <br /> Elevation: 10 ft Design TD (oF) 39 16 <br /> Latitude: 280N Relative humidity 50 50 <br /> Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 <br /> Dry bulb(oF) 31 91 Infiltration: <br /> Daily range(oF) - 14 L Method Simplified <br /> Wet bulb(°F - 77 Construction quality Semi-tight <br /> Wind speed (mph) 15.0 7.5 Fireplaces 0 <br /> IN <br /> -Component Btuh/ft2 Btuh % of load <br /> Walls 5.5 5191 31.9 Ucts <br /> Glazing 30.2 2683 16.5 <br /> U <br /> Doors 21.2 432 2.7 walls Infiltration <br /> Ceilings 1.7 60 0.4 <br /> Floors 4.1 4478 27.5 <br /> Infiltration 1.9 2039 12.5 <br /> Ducts 1400 8.6 <br /> g 0 0 <br /> Hupmidification 0 0 Glazing <br /> Floors <br /> 'I <br /> Ventilation 0 0 Doors Other <br /> Adjustments 0 <br /> Total- 1 162841 100.0 <br /> _Component Btuh/ft2 Btuh %of load <br /> Walls 2.8 2641 23.2 Internal Gains <br /> Glazing 56.3 5004 44.1 wall <br /> Doors 16.6 338 3.0 <br /> Ceilings 2.0 67 0.6 Ducts <br /> Floors 0 0 0 <br /> Infiltration 0.4 454 4.0 <br /> fl <br /> Ducts 1655 14.6 n ittration <br /> Ventilation 0 0 Other <br /> Internal gains 1200 10.6 Doors <br /> Blower 0 0 <br /> Adjustments 0 <br /> Total 11360 100.0 Glazing <br /> Latent Cooling Load= 1237 Btuh <br /> Overall U-value=0.150 Btuh/ft2_OF <br /> Data entries checked. <br /> ,,, + wrightsoft 2018-Feb-01 08:38:30 <br /> - Right-SufteO Universal 2017 17.0.23 RSU05714 <br /> ACC�k ...A27UHE AH'sk2575B sf ADS template 1.&2 ton.rup Calc=MJ8 Front Door faces: w Page I <br />