Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2575A1 sf ADS 2017 Builder Name: Lennar Homes <br /> Street: 6671 Wagon Trail Street Permit office: City of Zephyrhills <br /> City,State,Zip: Zephyrhills,FL, Permit Number: <br /> Owner: Lennar Homes ,jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ftz <br /> b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftz <br /> 4. Number of Bedrooms 4 d.N/A R= ftz <br /> 10.Ceiling Types (1491.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1491.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 2584 b.N/A R= ft2 <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11.Ducts R ftz <br /> 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 <br /> a. U-Factor: Dbl,U=0.54 71.25 ftz b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 71.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor: Dbl,U=0.56 33.33 ftz <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 17.5 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 1.190 ft. <br /> Area Weighted Average SHGC: 0.300 14.Hot water systems <br /> 8. Floor Types (2584.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftz b. Conservation features <br /> b.Floor Over Other Space R=0.0 1051.00 ftz None <br /> c.other(see details) R= 440.00 ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.77 PASS <br /> Total Baseline Loads: 74.82 <br /> I hereby certify that the plans and specifications covered by Review of the plans and S7:= <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: Dave Aulich Before construction is completed <br /> DATE: this buildingwill be inspected for <br /> P LL ... <br /> compliance with Section 553.908 <br /> I herebycertify that this building,as designed, is in compliance Florida Statutes. .� <br /> fY 9� 9 P <br /> with the Florida Energy Code. CIO <br /> OWNER/AGENT: BUILDING OFFICIAL. <br /> DATE: DATE: � <br /> - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.070 Qn for whole house. <br /> 2/1/2018 8:15 AM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 <br />