Laserfiche WebLink
r <br /> Building Analysis Job: 2575Alsf ADS2017 <br /> g y Date: 2/2812018 <br /> upper floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> Project I • • <br /> For: Lennar Homes <br /> ,Design • • • <br /> Location: Indoor: Heating Cooling <br /> Tampa International AP, FL, US Indoor temperature(°F) 70 75 <br /> Elevation: 10 ft Design TD (°F) 39 16 <br /> Latitude: 280N Relative humidity(%) 50 50 <br /> Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 <br /> Dry bulb(°F) 31 91 Infiltration: <br /> Daily range(°F) - 14 ( L ) Method Simplified <br /> Wet bulb(°F) - 77 Construction quality Semi-tight <br /> Wind speed (mph) 15.0 7.5 Fireplaces 0 <br /> Component Btuh/ftz Btuh % of load <br /> Walls 3.8 4219 32.8 u°t5 <br /> Glazing 30.2 2608 20.3 <br /> Doors 0 0 0 \Nall <br /> Ceilings 1.3 1870 14.6 nfiltration <br /> Floors 0 0 0 <br /> Infiltration 1.9 2307 17.9 <br /> Ducts 1846 14.4 <br /> Piping 0 0 <br /> Humidification 0 0 Ceilings <br /> Ventilation 0 0 Glazing <br /> Adjustments 0 <br /> Total 12850 100.0 <br /> FRO• • <br /> Component Btuh/ftz Btuh % of load <br /> Walls 2.7 3046 15.6 Walls <br /> Glazing 52.7 4554 23.3 <br /> Doors 0 0 0 Internal Gains <br /> Ceilings 1.7 2586 13.2 <br /> Floors 0 0 0 <br /> Infiltration 0.4 514 2.6 <br /> Ducts 2137 10.9 Glazing <br /> Ventilation 0 0 <br /> Internal gains 6725 34.4 <br /> Blower 0 0 <br /> Adjustments 0 <br /> Total 19562 100.0 Ceilings Infiltration <br /> Latent Cooling Load=2945 Btuh <br /> Overall U-value= 0.083 Btuh/ftz-°F <br /> Data entries checked. <br /> � + wrightsoft9 2018-Feb-28 11:35:32 <br /> ACCARight-Suite®Universal 2017 17.0.23 RSU05714 Page 2 <br /> ...BA27UHE AH's12575Asf ADS template 1.5-2ton.rup Calc=MJ8 Front Door faces:SE <br />