My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19516
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19516
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 10:22:27 AM
Creation date
1/31/2019 10:22:25 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19516
Building Department - Name
LENNAR HOMES LLC
Address
6671 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
--- - -- - -"- - -- - -- --- —t <br /> _ t <br /> , <br /> Ruildins;.unl(nst.uviceir,n 5:n iu•s(IKti7 <br /> 'Jul I <br /> i <br /> D sc <br /> A. <br /> C.c-)U N l-1' FLORIDA_, <br /> BI,ower Door TL Report Form <br /> Property Address: unit U, <br /> � <br /> L6 71 t ( P ! 3 I <br /> Perm"n tl: resting Company Name:SKYETEC j <br /> TestoaW �O Tmor HASSEN KNEI.IFI <br /> "Tester rent p:MY3YG6 904-903-1076 i <br /> Er.�i:1Tlclieliff@sk etec.com <br /> 402.4.1.2 Testing.Building envelope airtightness shall be demonstrated by Section 402.4.1 2 31 <br /> The building or dwelling unit shall be tested and vc feed as having an air leakage rate of no;exceeding 5 air changes F <br /> peT hour. Testing shall be conducted with a blower door at a ptkwsure of 0.2 inches w.g.(50 Pascals).As required by <br /> the Building Official,gating shall be conducted by an approved third pany.A wriHcn report of the results of the test <br /> shall be signed by the party conducting the teat(including Agency tame)and provided to the Building Official prior to j <br /> Certificate of Occupancy issuance.Testing shall be performed at any time after creation ofall scheduled penetrations of <br /> the building thermal envelope t <br /> During testingr(check to verify condition nw) <br /> I <br /> Exterior windows and doors,fireplace and stove do_ors shall be closed,but not sealed,beyond the intended weather- <br /> stripping or other <br /> t/]Dampers:including exhaust,intake,makeup air,backdraft and flue dampers shall be dosed,but not sealed beyond <br /> V mtendedinfiltration <br /> 1 <br /> Interior doors,if installed at the time of the test,shall be open j <br /> to Exterior doors for continuous ventilation systems and heat recovery ventilators shall be dosed and sealed <br /> V/ eating and cooling systems,if installed at the time of the test,shall be turned oft` <br /> upply and return registers,if installed at the.time`of the test,shall be fully open ! <br /> Vb Building volwne(113) <br /> Qso Airflow at 50"Pascal(CFM) _ ? <br /> I <br /> ACHso Air changes per hour at 500 Pascal <br /> Qso x 60-Vb ACHso(3.0 ACH minimum) i <br /> Pass Fail ! <br /> Outside Air mechanically introduced to space(less than 3.0 ACH) } <br /> 7 hereby cent fi,that the above envelope leakage performance results demonstrate compliance <br /> with Florida Energy Code requirements in accordance wit/r.Section R402.4.11. I <br /> Signature of Tesler Da e <br /> ` 1 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.