Laserfiche WebLink
Single F anvil Dwellin <br /> Y g <br /> Plan Review Comments <br /> 1. F.F.E. shall be aminimum:of.8",above,the road.elevation and an engineered,site plan. <br /> 2.. Lots shall be graded.to,comply with R401.3 of the F.B.C. <br /> 3. Compaction test required.if 24" or more.of .fill dirt is brought in at any one place: <br /> .4.. .Tie in survey required before pouring concrete.. <br /> 5.: Driveways require a R:O.W. use permit.. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material.. <br /> 6.. All.setbacks shall be met.:.'. <br /> 7.. All property-markers-shall be.uncovered and marked.at time of first inspection: - <br /> 8:. All A.D.A. requirements shall be met. <br /> 9.. No:electric,plumbing,_mechanical, or framing shall be covered without an-inspection and <br /> approval first. <br /> 10. All.Garages shall comply:with.section R302Aofthe.F.B:C.:.(Fire-S:eparation). <br /> 11.Appliances shall not:be installed in.a location where subject-to mechanical damage unless <br /> protected by approved barriers: M303.4 of the F B.0 <br /> 12. Water heaters shall.comply.with section P607.3 of the F.R.C. <br /> 13. Foundation supports for.A/C.units shall be raised at least 3" above finished grade,. M1308.1. <br /> 14. Return air in all,bedrooms..F.B.C. M1620.4. <br /> 15. Smoke detectors are.to be installed in-accordanee with.R313.1 of the F.B.C. <br /> .16.All glazing requirements are.to be'in accordance with R308.4,of the.F.B.C. <br /> 17. All means of egress are to be in:accordance with R311::of the R .C._ - <br /> 18. `.`Green gypsum board" shall not be used:as a backer in showers or tubs.R702.44.2 F.B.C. <br /> 19.'Combination-type AFCI breakers are required at all locations requiring an AFC type breaker: . . <br /> 20. Carbon monoxide.alarms will be required in new construetiori that uses fossil-burning heating <br /> :or appliances or an attached garage:. They shall be.installed in accordance with the F.B.C. <br /> 21._All plumbing,mechanical,:and-electrical shall be separate from unit.to.unit. This includes all <br /> underground plumbing and electric: <br /> 22."A112011.N.E.C. Codes:will be enforced: . <br /> 23.Tam er Resistant Receptacles' in accordance with 406.11 of the 201.1 N:E.0 <br /> p - � . . , . <br /> 24: Iri accordance.with the Land Development.Code; lots shall be sodded before final of least 10 <br /> ..feet around the structure: <br /> 25.A.cony of the energy Gaels shall be with permit at all times. <br /> 26 Copy ofrnal insulation report shall be.provided with permit.before finab <br /> F.F.E.=Finished Floor Elevation <br /> F:B.C=Florida Building Code 6h Edition <br /> R.O.W.-Right of Way <br /> A.D.A. Americans with.Disabilities Act N.E.C.-National Electric Code(2011): <br />