Laserfiche WebLink
Single. Family Dwelling <br /> Pla <br /> n Review.Comments <br /> 1: :F.F:E. shall be a.minimum of 8" above the road elevation.and an engineered site plan. <br /> -2. _Lots shall be' aded.to.comply with R401.3 of the F.B:.C: <br /> �' p.y <br /> 3. Compaction:test required.if 24" or more of f l dirt is brought in ai any one place: = <br /> 4: Tie in surveyrequired before pouring concrete.. . . <br /> 5. Driveways:require a R.O.W. use permit- All 4.sides of driveway that the sidewalk shall have <br /> expansion matenal:. <br /> 6.. All setbacks.shall.be.met..' . <br /> T- All pert markers shall be.uncovered and marked at time of first 'inspection: <br /> . pro pert p y <br /> 8:. .All A.D.A.-requirements shall-be met.:'. <br /> 9. No:electric;plumbing, meclianical;.or framing shall be covered'without aninspection and <br /> approval first. . <br /> 10. All Garages shall:comply with section R302:6.of the.F.B.C. (Fire Separation). <br /> I1. Appliances:shall not be installed in.a location where subiect:to mechanical darriage unless. . <br /> protected'by approved barriers. M303 4 ofthe F.B:C <br /> 12. Water heaters shall comply with section:P607.3 of the F.B.C. <br /> 13. Foundation supports for'A/C.units shall'be raised at least 3" above finished grade,. M1308.1 <br /> 14. Return-air in all:bedrooms..F.B.C. M.I620.4 <br /> 15. Smoke detectors are to be:installed in accordance:with.R3 III of theT.B.C. <br /> 16: All glazing requirements are:.to be in accordance with R308.4-'of the F.B.C. <br /> 17. All means.of egress are to be in:accordance with R311:of the F.B.C. :: - <br /> 18..`.`Green gypsum board shall not be used:as abacker.in7howers or tubs. R702.4:2.F.B.C. <br /> 19. Combination-type AFCI breakers'are.required:at all.locations requiring.an AFCI.type breaker: <br /> -20. Carbon motioxide alarms:will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage: ;They shaall-be-installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical,:and electrical shall be separate from unit to:unit: This includes all <br /> underground plumbing grid electric: <br /> 22. A112011:N.E.C. Codes will be enforced::. <br /> 23:Tamper-Resistant Receptacles in accordance with 406.11 of the 2011 N:E:C <br /> : 24::Iri accordance with the Land.Development:Code; lots shall be sodded before final of least 10 <br /> feet around the structure. <br /> 25.'A.cony of the energy caels shall be with hermit at all tinter. <br /> 26 Conv of final insulation report shall be.nrovided with Permit before rinab <br /> F:F:E.-Finished Floor Elevation <br /> F.B:C-•Florida Building Code 6a'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with.Disabilities Act N.E.C.-National Electric.Code(2011) . <br />