My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19518
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19518
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 10:24:24 AM
Creation date
1/31/2019 10:24:22 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19518
Building Department - Name
LENNAR HOMES LLC
Address
3258 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> 0099 <br /> Project Name: 1791 B1 sf ADS Builder Name: Lennar Homes <br /> Street: 3258 Moulden Hollow Drive Permit Office: City of Zephyrhills <br /> City,State,Zip: FL, Permit Number: <br /> 'Owner. Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 331.33 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 <br /> a. U-Factor: Dbl,U=0.54 87.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0:56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 23.00 ft2 <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency, <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 26.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.233 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features EF:0.950 <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.13 PASS <br /> Total Baseline Loads: 58.11 <br /> hereby certify that the plans and specifications covered by Review of the plans and . <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. ti <br /> PREPARED BY: Dave >4w'/h Before construction is completed <br /> DATE: this building will be inspected for �,�= - �C <br /> compliance with Section 553.908 <br /> I herebycertify that this building,as designed,is in compliance Florida Statutes. <br /> fY 9� 9 p <br /> with the Florida Energy Code. G'OD y`tg.1 <br /> OWNER/AGENT: BUILDING OFFI IAI <br /> DATE: DATE: <br /> 10, <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 8/9/2017 7:16 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Pagel of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.