Laserfiche WebLink
FORM R405-2014 <br /> WALLS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar Below <br /> 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 6 8 156.0 ft2 0 0.600000 0 <br /> 2 N=>NE Garage Frame-Wood Main 11 20 8 8 165.3 ft2 0 0.01 0 <br /> 3 W=>NW Garage Frame-Wood Main 11 20 9 8 166.0 ft2 0 0.01 0 <br /> 4 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 58 8 464.0 ft2 0 0.600000 0 <br /> 5 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0 <br /> 6 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 37 8 8 301.3 ft2 0 0.600000 0 <br /> 7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0 <br /> DOORS <br /> # Ornt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 <br /> 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2 <br /> WINDOWS <br /> Orientation shown is the entered orientation =>)changed to Worst Case. <br /> / Wall Overhang <br /> V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening <br /> 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 23.0 ft2 1 ft 0 in 4 ft 2 in Drapes/blinds None <br /> 2 E=>SE 4 Metal Low-E Double Yes 0.54 0.31 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None <br /> 3 S=>SW 5 Metal Low-E Double Yes 0.54 0.31 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None <br /> 4 S=>SW 7 Metal Low-E Double Yes 0.56 0.32 33.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None <br /> 5 W=>NW 6 Metal Low-E Double Yes 0.54 0.31 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None <br /> GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 427 ft2 427 ft2 42 ft 8 ft 1 <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000356 1695.9 93.1 175.09 .2669 7 <br /> HEATING SYSTEM <br /> # System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump None HSPF:8.5 26 kBtu/hr 1 sys#1 <br /> 8/9/2017 7:16 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 <br />