.Pro tSumma Job: R0318108 <br /> - - wrightsoft- ec ry Date: 0310812018 <br /> Entire House Br. MKc <br /> Teri Butterfield <br /> 37516 Cook Ave,Dade CO,FL <br /> Proeect Information <br /> For. Butterfield Investments Inc. <br /> 5023 Summer Hill Dr.,Yephyrhills,FL 33542 <br /> Notes: Load calculation was obtained from a digital copy of the CAD drawing. <br /> Design Information <br /> Weather. Tampa IntIAP,FL,US <br /> Winter DesignConditions Summer Design Conditions <br /> Outside db 43 OF" Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 27 OF Design TD. 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 grAb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 16769 Btuh Structure 16038 Btuh <br /> Ducts 4218 Btuh Ducts 6204 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 1365 Btuh <br /> Piping 0 Btuh <br /> Equipment load 20987 Btuh Use'manufacturers data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 23608 Btuh <br /> Method - Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality _ Average <br /> Fireplaces 0 Structure 2989 Btuh <br /> Ducts 1838 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Coolingg (none) <br /> Area(fF) 1781 1781 Equipment latent load 4827 Btuh <br /> Volume(ft� 14245 14245 <br /> Air changesAlour 0.38 0.20 Equipment Total Load(Sen+Lat) 28434 Btuh <br /> Equiv.AVF(cfm) 90 47 Req.total capacity at 0.73 SHR 2.7 ton <br /> Heating Equipment Summary Cooling Equipment Summary . <br /> Make Goodman Mfg.or Eqv. Make Goodman Mfg.or Eqv. <br /> Trade Split HP Trade Split HP <br /> Model GSZ16036 Cond GSZ16036 <br /> AHRI ref 8331286 Coil AVPTC36 <br /> AHRI ref 8331286 <br /> Efficiency 8.5 HSPF Efficiency 12.5 EER,15 SEER <br /> Heating Input Sensible cooling 23798 Btuh <br /> Heating output 34000 Btuh@47°F Latentcooling 8802 Btuh <br /> Temperature rise 28 OF Total cooling 32600 Btuh <br /> Actual air flow 1087 cfm Actual air flow 1087 dm <br /> Air flow factor 0.052 c rnBtuh Air flow factor 0.049 cb Btuh <br /> Static pressure - 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.83 <br /> Capacity balance point=31 OF <br /> Backup: Aux Heat <br /> Input=10 kW, Output=34121 Btuh,100 AFUE <br /> Calculations approved byACCA to meet all requirements of Manual J 8th Ed. <br /> wrigF�tsoft��~ -._•..a•. -....�.-..---..-. Right-SriteOUriversa1201818.0.10 RSU 2018-Mar-0915:04:1020773 Page 1 <br /> orkF1e1R0318106-SurvnerMllDrU20318106np Calc=MJS Frort Door faces:E <br />