Il Il FATTY ERD <br /> TABLE 2D:STEEL or STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER <br /> SYSTEM TYPE D-1: INSULATED,MECHANICALLY ATTACHED ROOF COVER <br /> Insulation tayer(Note 141 Roof Cover <br /> System DP <br /> Roof Dedc Type Attach Membrane Fasteners FastenerSpacing Lap width Lap spacing Scam Weld M <br /> (inch) (inch) (inch) (inch) <br /> Min,22 ga.,type B,Grade <br /> 33 steel,6 ft span,5/8" Mule-Hide TPO-c <br /> Min.1-inch,one or <br /> diameter puddle welds 6" Prelim, (min.nominal 60- Mute-Hide EHD Fastener and Mule-Hide <br /> SC-fii o.c.,side taps secured 24" more layers,any attach mll)or TPO-c 2.4"Seam Plate 6 5,5 114.5 1.5 45.0 <br /> o.c.w/%'"-14x1"long self- combination EXTRA <br /> tapping hex-head screw <br /> Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or <br /> SC-62 80 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 12 S.5 114.5 1.5 -45.0 <br /> structural concrete combination attach orTPO c EXTRA Hide 2.4"Seam Plate <br /> Min.22 Mule-Hide END Plus Fasteners and <br /> ga,type B,Grade more layers, <br /> ,one or Prelim. Mute-Hide TPO-c Mule-Hide 2.4"PLUS Seam Plate(steel <br /> SC-63 structural <br /> steel l min.2,500 psi more layers,any attach or TPO-c EXTRA only)or HDP Fastener and Mule-Hide 12 5.5 91 1.5 45.0 <br /> structural concrete combination 2.4"Seam Plates <br /> Min.22 ga.,type B,Grade Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or <br /> SC-64 80 steel or min.2,50D psi more layers,any Prelim. or TPOide EXTRA <br /> HDP Fastener(concrete only)and Mule- 12 SS 91 1.5 -45.0 <br /> structurai.concrete combination attach or TPO-c D(TRA Hide 2.4"Seam Plate <br /> Min.22 ga.,type B,Grade <br /> 33 steel,6 ft span,5/8' Min.1-inch,one or <br /> diameter puddle welds 6" Prelim. Mute-Hide TPO-c Mute-Hide EHD Fastener and Mule-Hide <br /> SG65 more layers,any o.c.,side laps secured 24" attach or TPO-c EXTRA 2.4"Seam Plate 6 5.5 66,5 1.5 45.0 <br /> o.c.w/3V-14x1"long self combination <br /> tapping hex-head screw <br /> Min.22 ga.,type 8,Grade <br /> 33 steel,6 it span,5/8" Mule-Hide TPD-c <br /> diameter puddle welds 6" Min.1-inch,one or Prelim. (min.nominal 60- Mule-Hide EHD Plus Fasteners and <br /> SC 66 o.c.,side laps secured 24" more layers,any attach mil)or TPO-c Mule-Hide 2.4"PLUS Seam Plate 6 S.5 114.5 1.5 -52.5 <br /> o.c.w/Y<"-14x1"long self Combination EXTRA <br /> tapping hex-head screw <br /> Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mute-Hide TPO-c Mule-Hide EHD Fastener(steel only)or <br /> SC 67 33 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 6 5.5 138.5 1.5 -52.5 <br /> structural concrete combination attach or7P4-c EXTRA Hide 2.4"Seam Plate <br /> Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or <br /> SC-68 33 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 6 5.5 91 1.5 52,5 <br /> structural concrete combination attach or TPO-c EXTRA Hide 2.4"Seam Plate <br /> Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report M15060.06.09-114 for FL32772-R4 <br /> Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION;Mule-Hide TPO-c Single Phr Roof Systems Revision 4:04/03/2017 <br /> Prepared by. Robert Nieminen,PE-S9166 Mule-Hide Products Co.,inc.;(608)365-3111 Appendix 1,Page 12 of 26 <br />