Laserfiche WebLink
TABLE 4B-2: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE—NEW CONSTRUCTION <br /> SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER <br /> System Roof Cover{Note 16} Mpp <br /> No. Deck(Note 1) Lightweight Concrete(Note 15) Membrane Application (psf) <br /> Min.2,500 psi structural <br /> lWC-9 Min.250 psi,Min,2"thick Elastizell Range it LWIC Mule-Hide TPO-c Aqua Base 120 BA 67.5 <br /> concrete <br /> Min.2,500 psi struttural <br /> LWC 10 Min.250 psi,Min.2"thick,Elastizell Range II LWIC(EPS board optional) Mule HideTPO-c TPO-c BA 240.0 <br /> concrete <br /> LWC-11 Min.2,500 psi structural Min 300 psi,Min.2"thick,Elastizell Range if LWIC(no EPS board) Mule-Hide TPO-c TPO-c BA -495.0 <br /> concrete <br /> LWC-12 Min.2,500 psi structural Min.390 psi,Min.2"thick,Celcore Cellular Concrete Mule-Hide TPO-c Aqua Base 120 BA -82.5 <br /> concrete <br /> LWC 13 Min.2,500 psi structural Min.300 psi,Min.2"thick,Celcore Cellular Concrete Mule-Hide TPO-c TPO-c BA -135.0 <br /> concrete <br /> LWC-14 Min.2,500 psi structural Min.36 pcf wet cast density,min.200 psi,min.2-inch thick Celcore MF Cellular Concrete(cast with Mule-Hide TPO-c Aqua Base 120 BA -217.5 <br /> concrete or without min.1"EPS holey board). Note A. <br /> LWC-15 Min.2,500 psi structural Min.36 pcf wet cast density,coin.200 psi,min.2-inch thick Cetcore MF Cellular Concrete(cast with Mute-Hide TPO-c TPO-c BA A80.0 <br /> concrete or without min.r EPS holey board). Note A. <br /> Note A.) if the type of LWC to be used on the project is unknown,as in a re-roof(tear-off)condition,compressive strength and fastener withdrawal resistance testing shall be conducted. Compressive Strength testing shall <br /> be in accordance with ASTM C495(for new pour)or ASTM C109(for existing)and shall yield a minimum 200 psi result. Field withdrawal resistance testing In accordance with TAS 105 or ANSIj5PRI FX-1 and shall yield an <br /> average withdrawal performance not less than S5 lbf with a Tnlfast FM-90 Base Sheet Fastener, if question exists as to the adhesion to the LWC surface,field testing In accordance with ASTM E907 or FM Loss Prevention <br /> Data Sheet 1-291s recommended.All testing shall be performed by an accredited testing agency acceptable to the Authority Having Jurisdiction. <br /> Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R4 for FL12772-R4 <br /> Certificate of Authorization#9S03 FBC NON-HVHZ EVALUATION;Mule-Hide TPO-c Single Ply Roof Systems Revision 4:04/03/2017 <br /> Prepared by: Robert Nieminen,PE-59166 Mute-Hide Products Co.,Inc.;(604)365-3121 Appendix 1,Page 20 of 26 <br />