Laserfiche WebLink
TABLE6E:RECOVERAPPLICATIONS <br /> SYSTEM TYPE F-2:NEW LIGHTWEIGHT CONCRETE OVER E)(ITISTING ROOF,BONDED ROOF COVER <br /> System Substrate(Notes 1&12) Roof Cover(Note 16) <br /> Lightweight Concrete(Note 15) MOP(psi) <br /> No. Deck Existing Roof Type Attach <br /> Structural Existing asphalt BUR or smooth-or granule-surface Min.250 psi,Min.2-Inch thick,Elastizeli Range II LWIC <br /> R-34 Mule Hide TPO c Aqua Base 120 BA 67.5 <br /> concrete SBS modified bitumen (EPS board optional) <br /> Structural Existing asphalt BUR or granule-Surface SBS modified Min.250 psi,Min.2-inch thick,Elastizell Range II LWIC <br /> R-35 concrete bitumen (EPS board optional) Mule Hide TPO c TPO-c BA 302.5 <br /> Structural Existing asphalt BUR or smooth-surface SBS modified Min.250 psi,Min.2-inch thick,Elostizell Range it LWIC <br /> R-36 Mule Hide TPO-c TPO c BA 342.0 <br /> concrete bitumen (EPS board optional) <br /> Exterior Research and Design,U.C.d/b/a Trinity ERD Evaluation Report M15060.06.09-R4 for FL12772-114 <br /> Certificate of Authorization 49503 FBC NON-HVHZ EVALUATION;Mule-Hide TPO-c Single Ply Roof Systems Revision 4:04/03/2017 <br /> Prepared by: Robert Nieminen,PE-59166 Mule-Hido Products Co.,Inc.;(668)365-3111 Appendix 1,Page 26 of 26 <br />