Laserfiche WebLink
P A PRODUCTS <br /> SilverUne <br /> INSTALLATION NOTES: SILVER L I A 1 E B 1 I L®I�1,/ �' bvAndersen <br /> 1. ONE(1)INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION LINE BUILDING~W■V"IA <br /> SHOWN. <br /> 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED 15 THE MINIMUM SERIES 70 MODEL 2127 <br /> NUMBER OF ANCHORS TO BE USED FOR PRODUCT INSTALLATION Of THE w I N o o sv c•o 0 0 h s <br /> MAXIMUM SIZE LISTED. ONE SILVEnLINE DRIVE <br /> 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF 21/2 EXTRUDED VINYL SINGLE HUNG WINDOW NORhl:(7OMU52435-1N7OB902 <br /> PH:(752)9a5-IODD <br /> INCH THE DEPICTED LOCATION&SPACING IN THE ANCHOR LAYOUT DETAILS <br /> (I.E.,WITHOUT CONSIDERATION OF TOLERANCES).TOLERANCES ARE NOT (NON—IMPACT) U m m <br /> CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. <br /> N 3 {Zy m Q <br /> 4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING w w ut N o 2 <br /> SHIM(S).MAXIMUM ALLOWABLE SHIM STACK TO BE 3/8 INCH.SHIM WHERE GENERAL NOTES: O Z�++ 11 u?m <br /> SPACE OF 1/16 INCH OR GREATER OCCURS.SHIM(S)SHALL BE CONSTRUCTED ri {-2 u °= <br /> OF HIGH DENSITY PLASTIC OR BETTER. 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND o = <br /> MANUFACTURED TO COMPLY WITH THE 6TH EDITION n Z ¢ z m U <br /> S. FIN INSTALLATION:FOR INSTALLATION INTO WOOD FRAMING USE 08 WOOD FLORIDA BUILDING CODE(FBC),INCLUDING HVHZ AND HAS w 2 w m <br /> SCREWS OR 11 GAUGE ROOFING NAILS OR 10d COMMON NAILS OF SUFFICIENT BEEN EVALUATED ACCORDING TO THE FOLLOWING: P I- j o J H m e <br /> LENGTH TO ACHIEVE 1-1/2 INCH MINIMUM EMBEDMENT INTO WOOD TAS 202-94 LLuC t9 <br /> • m <br /> SUBSTRATE.INSTALLATION SHALL MAINTAIN MIN.3/8"EDGE DISTANCE. ASTM E330-02 Z UJ be ZI..r Oc <br /> • AAMA/WDMA/CSA 101/1.5.2/A990-08/11 W h ¢ w p n <br /> 6. FIN INSTALLATION:FOR INSTALLATION INTO METAL STUD USE R8 TABLE OF CONTENTS H-1 W rn <br /> SELF-TAPPING SCREWS,OF SUFFICIENT LENGTH TO ACHIEVE A MINIMUM OF 3 2. ADEQUACY OF THE EXISTING STRUCTURAL t1C r^ <br /> THREADS PENETRATION BEYOND METAL WALL.INSTALLATION SHALL MAINTAIN CONCRETE/MASONRY,2X FRAMING,AND METAL FRAMING SHEET REVISION SHEET DESCRIPTION o_ <br /> MIN.3/8"EDGE DISTANCE. AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF <br /> WITHSTANDING AND TRANSFERRING APPLIED PRODUCT 1 - INSTALLATION 8 GENERAL NOTES <br /> 7. THROUGH FRAME INSTALLATION:FOR INSTALLATION INTO WOOD FRAMING LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE 2 _ ELEVATION 6 ANCHOR LAYOUTS <br /> USE II30 WOOD SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 1-1/2 INCH ENGINEER OR ARCHITECT OF RECORD F00.THE PROJECT OF <br /> MINIMUM EMBEDMENT INTO WOOD SUBSTRATE. INSTALLATION. 3 - VERTICAL 6 HORIZONTAL SECTIONS(NAIL FIN) <br /> m <br /> 8. THROUGH FRAME INSTALLATION:FOR INSTALLATION THROUGH 1X BUCK TO 3. 1X AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED AND 4 - VERTICAL&HORIZONTAL SECTIONS(THROUGH FRAME) <br /> CONCRETE/MASONRY,OR DIRECTLY INTO CONCRETE/MASONRY,USE 3/16 INCH ANCHORED AS SPECIFIED HEREIN.REFER TO SHEET 5 FOR 5 HORIZONTAL SECTIONS,BUCK INSTALLATION,GLAZING <br /> DIAMETER ITW TAPCONS OF SUFFICIENT LENGTH TO ACHIEVE 1-1/4 INCH FURTHER DETAILS OF BUCK INSTALLATION. - DETAIL,6 REINFORCEMENT Z <br /> MINIMUM EMBEDMENT.INSTALLATION SHALL MAINTAIN MIN.1 3/4"EDGE 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE O <br /> DISTANCE. GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR H Z <br /> 9. THROUGH FRAME INSTALLATION:FOR INSTALLATION INTO METAL STUD USE A SPECIFIC SITE.IF SITE CONDITIONS CAUSE INSTALLATION <br /> RID SELF-TAPPING SCREWS OF SUFFICIENT LENGTH TO ACHIEVE A MINIMUM A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITEO- <br /> OF 3 THREADS P NETRATION BEYOND METAL WALL. SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT IN Oc <br /> U <br /> 10. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, NON-HVHZ AREAS.IN HVHZ AREAS,ONETIME PRODUCT w <br /> APPROVAL TO BE OBTAINED FROM MIAMI-DADE RER OR LLU <br /> INCLUDING BUT NOT LIMITED TO STUCCO,FOAM,BRICK VENEER,AND SIDING. AHJ Q.I p <br /> 11. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF S. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED ON MAX OVERALL SIZE <br /> CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. DESIGN MISSILE <br /> COATING. CONFIG. <br /> WIDTN HEIGHT PRESSURE IMPACT RATING <br /> 12. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK,DO NOT INSTALL 6. WINDOW FRAME MATERIAL:PVC <br /> 1(Dll I1J 11/ <br /> INSTALLATION ANCHORS INTO MORTAR JOINTS.EDGE DISTANCE IS MEASURED 7, IN ACCORDANCE WITH THE 6TH EDITION FBC,WOOD 52" 62.50" O/X •62.0/-65 PSF NON IMPACT Z <br /> FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF COMPONENTS SHALL HAVE BEEN PRESERVATIVE TREATED Q' ti7 Aipp,,�° <br /> BLOCK. OR SHALL BE OF A DURABLE SPECIES AS DEFINED IN 52" 73" O/X *55/-60 P5F NON IMPACT �-;<� a <br /> CHAPTER 23. 2 <br /> 13. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR r�i �•. ' <br /> MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE 8. GLASS MEETS THE REQUIREMENTS Of ASTM E 1300 R <br /> USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH GLASS CHARTS.SEE SHEET S FOR GLAZING DETAILS. <br /> SPECIFIED BY THE ANCHOR MANUFACTURER. = ~ •" <br /> 75 <br /> 14. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON �y <br /> SUBSTRATE MATERIALS WITH THE FOLLOWING PROPERTIES: �i d'�y O� - <br /> A.WOOD-MINIMUM SPECIFIC GRAVITY OF 0.55. iA Pfi W <br /> B.CONCRETE-MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. /yy1111*I 1111LL1Y <br /> C.GROUT-FILLED CMU-UNIT STRENGTH CONFORMS TO ASTM C-90 WITH <br /> MINIMUM COMPRESSIVE STRENGTH OF 20DO PSI AND GROUT CONFORMS <br /> TO ASTM C 476,MINIMUM GROUT COMPRESSIVE STRENGTH OF 2000 PSI. �L Do U) OD <br /> MI J LA <br /> D.HOLLOW BLOCK CMU-UNIT STRENGTH CONFORMS TO ASTM C-90 WITH Q Do V) 2:LL U Z <br /> MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI, <br /> E. STEEL-MINIMUM YIELD STRENGTH OF 33 KSI.MINIMUM WALLTHICKNESS p U L.) <br /> OF 47.8 MIL(0.0478"or 18 GAUGE).MIN.1/2"EDGE DISTANCE. <br /> F. ALUMINUM-MINIMUM ALLOY 6063-TS.MINIMUM WALL-THICKNESS OF DWG#`:. ' ,L <br /> 1/16".MIN.1/2"EDGE DISTANCE. 5 VI/D O 1 O <br /> Digitally signed by Hermes F.NDrero,P.E. YY <br /> Reason:I am approving this document FL#: FL 19715 <br /> Date:2017.06.1421:59:50-04'00' SHEET: 1 OF <br />