Laserfiche WebLink
This home has been professionally insulated with <br /> • Owens Corning <br /> PROPINKO L77 Loosefill Insulation <br /> Name <br /> Address `�((/12 �Q( �I Ct P �6 h Ir <br /> City 2 State FL Zip <br /> yr <br /> Owens Corning O PROPINKO L77 Loosefill Insulation <br /> Owens Coming Insulating Systems,LLC will accept no responsibility when the product is not installed in accordance with the product label.Stated R-value is <br /> provided by installing the required number of bags at a thickness not less than the labeled minimum thickness.Installation of the required number of bags <br /> may yield more than the specified minimum thickness.Failure by the,installer to provide both the required bags and at least the minimum thickness will result <br /> in lower insulation R-value. <br /> Specification for Open Attics Coverage charts are based on a nominal net ba <br /> Blow Attics Minimum Maximum Minimum weight of 32lbs. 9 <br /> n Initial Minimum Coverage Minimum Weight g <br /> New Construction �+�� Installed Settled Per Bag Bags Per (Ibs per Walls <br /> Retrofit Thickness ' <br /> R-value Thickness' (sq.ft.) 1000 sq.ft sq.ft.) <br /> (inches) <br /> _Number of bags used � Minimum <br /> 13 4.75 4.75 184.6 5.4 0.173` <br /> Estimated nsulue of - <br /> Initial Installed Maximum Minimum Minimum <br /> 19 7.00 7.00 125 8.0 0.256 <br /> previous insulation 2P 8.00 8.00 106.3 9.4 0.301 Installed Density Coverage Bags Per Weight <br /> Area of coverage.?�1'1 26 9.25 9.25 89.6 11.2 0.357 R- Thickness (Ibs.per Per Bag 1000 (Ibs.per <br /> (sq.ft.) J ` U 30 10.50 10.50 77.0 13.0 0.416 value Framing (inches) cu:ft.) (sq.ft.) sq.ft. sq.ft.) <br /> Othertype(s)of 38 13.25 13.25 59.5 16.7 0.534 14 2x4 3.5 '1.25 - 87.8 114 0364 <br /> Insulation in attic 44 15.00 15.00 50.7 19.7 0.631 15 2x4 3.5 1.45 75.7 132 0423 <br /> Thickness of 1 / 49 16.75 16.75 45 22.2 0.711 16 2x4 3.5 2.20 49.9 201 0.642 <br /> insulation 60 20.00 20.00 .35.8 28.0 0.895 22 2x6 5.5 1.25 55.9 179 0573 <br /> Depth of previous 23 2x6 5.5 1.35 51.7 19 3 0.619 <br /> insulation 24 2x6 5.5 1.75 40.0 25.0 0.802 <br /> Cathedral Ceiling Floors <br /> Minimum InstalledMaximum Minimum Minimum <br /> Initial Minimum Installed Density Coverage Bags Per Weight Minimum <br /> _ Installed Initial, Density Maximum Minimum <br /> R Framing Thickness (Ibs.per Per Bag 1000 sq. (Ibs.per Installed ty Coverage Bags Per Weight <br /> value cu,ft s .ft ft. sq.fc (Ibs.per (Ibs.per <br /> (inches) ) ( q ) q ) R- Framing Thickness cu.ft) Per 1000 s ft. <br /> 30 2x8 7.25 1.35 39.2 25.5 0.816 value (inches) Bag(sq.ft.) sq.ft. q ) <br /> 38 2x10 9.25 1.35 30.8 32.5 - 1.041 30 2x8 7.25 1.35 39.2 255 0841 <br /> 49 2x12 11.25 1.85 18.5 64.2 1.734 38 2x10 9.25 1.35 30.8 32.2 1041 <br /> 46 2x12 11.25 1.35 25.3 39.6 1266 <br /> Owens Coming(R)glass fiber blanket and loosefill thermal insulations,when installed per the manufacturers'coverage charts and recommendations,will <br /> provide the labeled R-Value. <br /> THE FOLLOWING PRODUCTS HAVE BEEN INSTALLED IN THIS HOUSE. <br /> Kraft Unfaced Foil Loosefill FS-25 R-value Thicknes pkgs Coverage <br /> Area <br /> Ceilings 0 0 0 0 0 <br /> 0 0 0 0 0 <br /> Floors 0 0 0 0 0 - <br /> 0 0 0 0 0 <br /> Walls 0 0 0 0 0 <br /> 0 0 0 0 0 <br /> Basement 0 0 0 0 0 <br /> 0 0 0 0 0 <br /> Crawlspace 0 0 0 0 0 <br /> 0 0 0 0 0 <br /> Attic 0 0 0 0 0 ; - <br /> 0 0 17 0 0 <br /> Contractor Daniel Insulation Date Builder <br /> Date <br /> Company Company <br /> (Signature) (Signature) <br /> Address 12950 Daniel Dr. Address <br /> Phone (727)572-8990 Phone <br /> OWENS CORNING INSULATING SYSTEMS,LLC <br /> ONE OWENS CORNING PARKWAY <br /> TOLEDO,OHIO,USA 43659 Pub.No.10018804-C.Printed in U.S.A.October 2016.The color PINK is a <br /> registered trademark of Owens Corning.@2016 Owens Coming Insulating <br /> S 1-800-GET-PINKO Systems,LLC.All rights reserved. <br /> www.owenscorning.com <br />